2022
DOI: 10.1155/2022/2830299
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of Shear Bond Strength of Resin-Based Composites to Biodentine with Three Types of Seventh-Generation Bonding Agents: An In Vitro Study

Abstract: Background and Aim. Biodentine refers to a bioactive material commonly applied for dental restoration in clinical practice, but poor adhesion of the Biodentine to the restorative materials could affect the quality and long-term integrity of the final restoration. The study aimed to assess shear bond strength (SBS) of two resin-based composites to Biodentine using three commercially available 7th generation bonding agents. Methods. Forty-eight acrylic blocks having central holes with a nominal diameter of 4 mm … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 37 publications
(58 reference statements)
0
2
0
Order By: Relevance
“…[73] This can lead to complications such as recurrent decay, microleakage, infection, hypersensitivity, inflammation, and eventually restoration failure. [74] For larger implant fixation in which bone cements are frequently used to stabilize the implant in place, the weak or worn-off adhesion strength at the implant-bone interface can lead to dislocation of the implants. For example, in a report about unicompartmental knee replacement, [75] the implant loosening was not detectable within few months postoperation nor impacted any daily activities, although the 60-year-old male patient was experiencing mild pain.…”
Section: Internal Tissue Adhesivesmentioning
confidence: 99%
See 1 more Smart Citation
“…[73] This can lead to complications such as recurrent decay, microleakage, infection, hypersensitivity, inflammation, and eventually restoration failure. [74] For larger implant fixation in which bone cements are frequently used to stabilize the implant in place, the weak or worn-off adhesion strength at the implant-bone interface can lead to dislocation of the implants. For example, in a report about unicompartmental knee replacement, [75] the implant loosening was not detectable within few months postoperation nor impacted any daily activities, although the 60-year-old male patient was experiencing mild pain.…”
Section: Internal Tissue Adhesivesmentioning
confidence: 99%
“…[ 73 ] This can lead to complications such as recurrent decay, microleakage, infection, hypersensitivity, inflammation, and eventually restoration failure. [ 74 ]…”
Section: The Need For Hydrogel–tissue Adhesionmentioning
confidence: 99%