2012
DOI: 10.1007/s11581-012-0749-1
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of solid electrolyte cells with a versatile electrochemical technique

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2012
2012
2021
2021

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 12 publications
0
5
0
Order By: Relevance
“…As-received 5.5070 (7) 13.3929 (5) i n t e r n a t i o n a l j o u r n a l o f h y d r o g e n e n e r g y 3 7 ( 2 0 1 2 ) 1 9 0 9 2 e1 9 1 0 2 subjected to galvanostatic current interruption (GCI) under multiple currents at 804 C. The details of GCI measurement procedures and equipment used are presented in [14]. Briefly the GCI technique enables separation of electrolyte resistance and polarisation losses if a fast current interrupt switch is used and the voltage decay after current interruption is recorded using a fast data acquisition system.…”
Section: Samplementioning
confidence: 99%
“…As-received 5.5070 (7) 13.3929 (5) i n t e r n a t i o n a l j o u r n a l o f h y d r o g e n e n e r g y 3 7 ( 2 0 1 2 ) 1 9 0 9 2 e1 9 1 0 2 subjected to galvanostatic current interruption (GCI) under multiple currents at 804 C. The details of GCI measurement procedures and equipment used are presented in [14]. Briefly the GCI technique enables separation of electrolyte resistance and polarisation losses if a fast current interrupt switch is used and the voltage decay after current interruption is recorded using a fast data acquisition system.…”
Section: Samplementioning
confidence: 99%
“…These two arcs encompass the polarization resistance from both anode and cathode. The contribution of LSCF cathode to the EIS of the cell must be negligible as demonstrated in our previous study [19]. Thus, the two arcs in both Ag-LSCF and Pd-Ag-LSCF electrode can be attributed to anode processes including diffusion, charge transfer, gas adsorption/desorption and hydrogen splitting on the MIEC electrode surface as well as the electrolyte / electrode interface.…”
Section: Temperature Effects On Ocv and Performancementioning
confidence: 58%
“…It should be noted that, for both cells, the electrolyte disk was fabricated from the same batch. Thus, differences could be at- The contribution of the LSCF cathode to the EIS of the cell must be negligible, as demonstrated in our previous study [20]. Thus, the two arcs in both the Ag-LSCF and Pd-Ag-LSCF electrodes can be attributed to anode processes including diffusion, charge transfer, gas adsorption/desorption and hydrogen splitting on the MIEC electrode surface, as well as the electrolyte/electrode interface.…”
Section: Electrode Performances With Hydrogen Fuelmentioning
confidence: 64%