Abstract: Instrument transformers are largely used to measure voltages and currents in public electricity networks. Their performance is essential for Power Quality measurements. Tests and procedures to estimate the effect of single influence factors are performed according to current standards. However, the instrument transformers are exposed simultaneously to more than one factor. The standardized procedures for their characterization with combined influence factors are under construction in Europe. The work in this p… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
7
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3
2

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(8 citation statements)
references
References 12 publications
1
7
0
Order By: Relevance
“…The change in the temperature shifts the resonance frequencies as the winding geometry changes: with rising temperature, the resonance frequency decreases. Therefore, in the region close to the resonances, the ratio error for a given frequency can change in the range of 100% [ 31 ].…”
Section: Experimental Results: Effect Of Single Influence Quantitymentioning
confidence: 99%
See 3 more Smart Citations
“…The change in the temperature shifts the resonance frequencies as the winding geometry changes: with rising temperature, the resonance frequency decreases. Therefore, in the region close to the resonances, the ratio error for a given frequency can change in the range of 100% [ 31 ].…”
Section: Experimental Results: Effect Of Single Influence Quantitymentioning
confidence: 99%
“…Similar observations were made when measuring the frequency response of the VT. However, at low temperatures, the deviations were more noticeable, regardless of the presence of vibration [ 31 , 40 ].…”
Section: Experimental Results: Effect Of Multiple Influence Quantitiesmentioning
confidence: 99%
See 2 more Smart Citations
“…The impact of external factors on instrument voltage transformer frequency response behavior is covered in [111][112][113]. These factors do not include certain issues, such as transducer design aspects and inherent errors due to manufacturing processes, since they are considered as internal factors.…”
Section: Impact Of External Factors On Instrument Transformer Frequen...mentioning
confidence: 99%