2022
DOI: 10.1007/s00405-022-07265-2
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of the Bonebridge BCI 602 active bone conductive implant in adults: efficacy and stability of audiological, surgical, and functional outcomes

Abstract: Purpose (1) To assess the effectiveness and safety of a bone-conduction implant, the Bonebridge BCI 602, in adults with conductive or mixed hearing loss. (2) To investigate whether the Bonebridge BCI 602 is at least as effective as the Bonebridge BCI 601 in such patients. Methods The study group included 42 adults who had either conductive or mixed hearing loss. All patients underwent Bonebridge BCI 602 implant surgery. Before and after implantation, pure-… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
54
0
1

Year Published

2023
2023
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 17 publications
(57 citation statements)
references
References 41 publications
1
54
0
1
Order By: Relevance
“…The reduced thickness of the BCI 602 floating mass transducer has been suggested to reduce complications and surgical time. Cywka et al (3) reported a slightly shorter operation time for BCI 602 (mean, 28.3 ± 9.4 min; n = 42) compared with BCI 601 implantations (mean, 35.6 ± 8.1 min; n = 10). In our cohort, average surgical duration of BCI 602 implantation (94 ± 42 min) was shorter than BCI 601 implantation (109 ± 39 min), although significance was not reached ( p > 0.05).…”
Section: Discussionmentioning
confidence: 98%
See 1 more Smart Citation
“…The reduced thickness of the BCI 602 floating mass transducer has been suggested to reduce complications and surgical time. Cywka et al (3) reported a slightly shorter operation time for BCI 602 (mean, 28.3 ± 9.4 min; n = 42) compared with BCI 601 implantations (mean, 35.6 ± 8.1 min; n = 10). In our cohort, average surgical duration of BCI 602 implantation (94 ± 42 min) was shorter than BCI 601 implantation (109 ± 39 min), although significance was not reached ( p > 0.05).…”
Section: Discussionmentioning
confidence: 98%
“…This allows for less drilling depth while providing the same power output, reducing the risk of exposing or compressing the regional dura or sigmoid sinus. The external audio processor is the same for both devices (3).…”
Section: Introductionmentioning
confidence: 99%
“…Literatura krajowa i zagraniczna uwzględniająca wyniki audiologiczne oraz subiektywne wrażenia użytkowników potwierdza skuteczność wszczepialnych urządzeń wykorzystujących kostne przewodnictwo dźwięku u pacjentów z przewodzeniowym i mieszanym ubytkiem słuchu [2][3][4][5].…”
Section: Wstępunclassified
“…Fewer surgical steps also simplify and shorten the surgical procedure. The dimensions of the BCI 602 (MRI-conditional at 1.5 T) and its predecessor, the BCI 601, were described in a monocentric study by Cywka et al [ 8 ] (see also Fig. 1 a + b).…”
Section: Introductionmentioning
confidence: 99%