2016
DOI: 10.1016/j.ast.2016.03.001
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of the effectiveness of typical casing treatments for a low-speed compressor by an integral method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
5
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 12 publications
(5 citation statements)
references
References 12 publications
0
5
0
Order By: Relevance
“…At the same time, the same CFD result at the near stall point of the smooth casing was used to construct the bell curve and compare it with those of the smooth casing, a double-grooved casing (generated separately for another paper [16]), a five-grooved casing, and a SAS casing. The resultant bell curves are depicted in [19], which predicted that the SMI of SELF-INJ should be similar to the double-grooved CG13 (not shown in the figure), much less than the other two casing treatments. The test results are given in Table 2 [19], which confirmed the prediction in Figure 19.…”
Section: Tip Air Injection With Self-recirculationmentioning
confidence: 99%
See 3 more Smart Citations
“…At the same time, the same CFD result at the near stall point of the smooth casing was used to construct the bell curve and compare it with those of the smooth casing, a double-grooved casing (generated separately for another paper [16]), a five-grooved casing, and a SAS casing. The resultant bell curves are depicted in [19], which predicted that the SMI of SELF-INJ should be similar to the double-grooved CG13 (not shown in the figure), much less than the other two casing treatments. The test results are given in Table 2 [19], which confirmed the prediction in Figure 19.…”
Section: Tip Air Injection With Self-recirculationmentioning
confidence: 99%
“…The resultant bell curves are depicted in [19], which predicted that the SMI of SELF-INJ should be similar to the double-grooved CG13 (not shown in the figure), much less than the other two casing treatments. The test results are given in Table 2 [19], which confirmed the prediction in Figure 19.…”
Section: Tip Air Injection With Self-recirculationmentioning
confidence: 99%
See 2 more Smart Citations
“…As a flow control technology, the circumferential groove was widely used to improve the flow stability of the compressor. [26][27][28] The performance enhancement mechanism of the circumferential groove can be summarized in three aspects. First, the circumferential groove had a positive impact on the TLF.…”
Section: Introductionmentioning
confidence: 99%