2013
DOI: 10.1155/2013/670947
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of the HB&L System for the Microbiological Screening of Storage Medium for Organ-Cultured Corneas

Abstract: Aims. To compare HB&L and BACTEC systems for detecting the microorganisms contaminating the corneal storage liquid preserved at 31°C. Methods. Human donor corneas were stored at 4°C followed by preservation at 31°C. Samples of the storage medium were inoculated in BACTEC Peds Plus/F (aerobic microorganisms), BACTEC Plus Anaerobic/F (anaerobic microorganisms), and HB&L bottles. The tests were performed (a) after six days of storage, (b) end of storage, and (c) after 24 hours of preservation in deturgescent liqu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
5
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 17 publications
1
5
0
Order By: Relevance
“…Limitations of the automated system in detecting filamentous fungi have also been observed by other authors. 15 In our study, the system showed positive readings for A. brasiliensis when the incubation time was extended to 5 days. Therefore, according to our findings, the incubation time of the sample should be extended from 48 hours to 5 days at least, in order to include the detection of filamentous fungi.…”
Section: Discussionsupporting
confidence: 52%
See 3 more Smart Citations
“…Limitations of the automated system in detecting filamentous fungi have also been observed by other authors. 15 In our study, the system showed positive readings for A. brasiliensis when the incubation time was extended to 5 days. Therefore, according to our findings, the incubation time of the sample should be extended from 48 hours to 5 days at least, in order to include the detection of filamentous fungi.…”
Section: Discussionsupporting
confidence: 52%
“…First, unlike other automated systems such as the BACTEC blood culture system, 18 the HB&L system does not implement any antimicrobial removal or neutralisation process; second, as reported by other authors, the sample volume is restricted to 500 µL. 15 Our findings showed that the presence of streptomycin sulfate and penicillin G, which are known to be effective in reducing the bioburden of contaminated tissues, 19 in the tested media clearly interfered with the microbial growth during sterility testing and resulted in FN results. In fact, the automated system did not detect the presence of four ( B. subtilis , C. sporogens , P. aeruginosa and S. aureus ) out of six microbial strains after inoculation in TISSUE-C and CARRY-C media at 1–10 and 2–20 cfu/mL, respectively.…”
Section: Discussionmentioning
confidence: 98%
See 2 more Smart Citations
“…Antibacterial agents such as penicillin and streptomycin, and antifungal agents such as amphotericin B are usually used as an empiric cocktail in OC corneal preservation media. Conventional microbiological controls are currently performed using standard bacteriological media in aerobic and anaerobic environments, whereas Sabouraud broth is a routine medium for detection of fungi 24. Other options include the use of Bactec blood bottles (Becton Dickinson) incubated in the Bactec instrument (based on the detection of CO 2 produced by microorganisms), which offer many advantages over the standard microbiological techniques 25–27.…”
Section: Discussionmentioning
confidence: 99%