Conference Record of the 2006 IEEE International Symposium on Electrical Insulation
DOI: 10.1109/elinsl.2006.1665273
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of the Insulation of 15 kV – 25 kV Feeders and Procedures for Substitution of Damaged Units

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
9
0

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(9 citation statements)
references
References 0 publications
0
9
0
Order By: Relevance
“…As a result, approximately 19.2% of insulators that could be considered as being undamaged were tested at the high voltage laboratory. This figure was higher if compared to the first part of the research [1], in which 11.22% of undamaged insulators were removed and tested at the high voltage laboratory. This explains part of the differences observed in these two research studies between the success and error indexes of the detector antenna.…”
Section: Field Inspectionsmentioning
confidence: 77%
See 3 more Smart Citations
“…As a result, approximately 19.2% of insulators that could be considered as being undamaged were tested at the high voltage laboratory. This figure was higher if compared to the first part of the research [1], in which 11.22% of undamaged insulators were removed and tested at the high voltage laboratory. This explains part of the differences observed in these two research studies between the success and error indexes of the detector antenna.…”
Section: Field Inspectionsmentioning
confidence: 77%
“…This explains part of the differences observed in these two research studies between the success and error indexes of the detector antenna. In order to try to avoid some previous drawbacks [1], the present research considers ground measurements of relative air humidity, local temperature, and wind speed. There may be some dissent about the fact that all the weather measurements were taken from the ground and no pole height correction factor was considered.…”
Section: Field Inspectionsmentioning
confidence: 99%
See 2 more Smart Citations
“…On the other hand, the indiscriminate replacements of aged components are considered uneconomical, and ultrasonic noise detectors appear as a good option for inspection of insulators in distribution networks [3][4]. Note that insulators can perform well in the field for decades, without any problem, but many could present some incipient state of failure.…”
Section: Introductionmentioning
confidence: 99%