1988
DOI: 10.1016/s0272-6386(88)80208-7
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of the Lysis-Centrifugation System for Culturing Dialysates From Continuous Ambulatory Peritoneal Dialysis Patients With Peritonitis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
5
0

Year Published

1989
1989
2023
2023

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(5 citation statements)
references
References 17 publications
0
5
0
Order By: Relevance
“…Investigators have found numbers of microorganisms in peritonitis that ranged from 1 CFU/ml to "too numerous to count" (36,40,82,116,136). Gram-positive organisms had higher mean counts than gram-negative rods (36,82,116).…”
Section: Cultivation Of Microorganisms General Principlesmentioning
confidence: 99%
See 1 more Smart Citation
“…Investigators have found numbers of microorganisms in peritonitis that ranged from 1 CFU/ml to "too numerous to count" (36,40,82,116,136). Gram-positive organisms had higher mean counts than gram-negative rods (36,82,116).…”
Section: Cultivation Of Microorganisms General Principlesmentioning
confidence: 99%
“…It performed as well as the Isolator system (DuPont Co., Wilmington, Del.) with 10 ml of dialysate (40,155), although detection with the latter was 24 to 72 h earlier in 20% of the isolates (40 (82). A lower incubation temperature was favored for fungal cultures (156) and for psychrophiles such as P. fliuorescens (82), P. mesophilica (118), and Rhodotorula glutinis (154).…”
Section: Clin Microbiol Revmentioning
confidence: 99%
“…However, comparative studies indicate that the minimum volume that should be tested is 10 ml (5,13,15,21). The method chosen should include an enrichment broth with antiphagocytic and lytic properties (3,18,19). Both centrifugation (12,13,20) and filtration (11)(12)(13)(14)20) have been tested as means of concentrating bacteria from CAPD effluents.…”
mentioning
confidence: 99%
“…It performed as well as the Isolator system (DuPont Co., Wilmington, Del.) with 10 ml of dialysate (40,155), although detection with the latter was 24 to 72 h earlier in 20% of the isolates (40). In another study identification (but not isolation) was 24 to 48 h earlier with the Isolator than the BACTEC, and the Isolator performed equally as well as culture of 50 ml of plated and enriched centrifuged sample in nearly all respects (155).…”
Section: Downloaded Frommentioning
confidence: 93%
“…A few quantitative studies on dialysates have been done. Investigators have found numbers of microorganisms in peritonitis that ranged from 1 CFU/ml to "too numerous to count" (36,40,82,116,136). Gram-positive organisms had higher mean counts than gram-negative rods (36,82,116).…”
Section: General Principlesmentioning
confidence: 99%