2016
DOI: 10.1111/vaa.12281
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of the non-calibrated pulse contour cardiac output monitor FloTrac/Vigileo against thermodilution in standing horses

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
2
2

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 41 publications
0
3
0
Order By: Relevance
“…Measurement of the cardiac output could have been interesting for a better understanding of the cardiac performance. However, in the presence of a VSD none of the indicator dilution techniques can be used to determine cardiac output (Hallowell and Corley 2005, Kutter and others 2016). Alternatively, oesophageal echocardiography could have been used to estimate the cardiac output (Young and others 1996), perianaesthetic shunt fraction and cardiac contractility, but it was not available in this case.…”
Section: Discussionmentioning
confidence: 99%
“…Measurement of the cardiac output could have been interesting for a better understanding of the cardiac performance. However, in the presence of a VSD none of the indicator dilution techniques can be used to determine cardiac output (Hallowell and Corley 2005, Kutter and others 2016). Alternatively, oesophageal echocardiography could have been used to estimate the cardiac output (Young and others 1996), perianaesthetic shunt fraction and cardiac contractility, but it was not available in this case.…”
Section: Discussionmentioning
confidence: 99%
“…Monitoring CO during equine anaesthesia is mainly reserved for research (Kutter et al., 2016). Despite this, CO measurement may enable guided fluid resuscitation and choice of cardiac support drugs during general anaesthesia (Corley et al., 2003) yet is rarely done in practice.…”
Section: Advanced Methods Of Monitoringmentioning
confidence: 99%
“…Most devices require repeated calibration with lithium dilution or thermodilution techniques (Bendjelid, 2009). Conflicting evidence exists regarding the accuracy of devices in anaesthetised horses and foals (Hallowell & Corley, 2005; Schauvliege et al., 2009; Shih et al., 2009) with noncalibrated devices proving inaccurate (Kutter et al., 2016). Routine clinical use of pulse contour analysis cannot currently be recommended.…”
Section: Advanced Methods Of Monitoringmentioning
confidence: 99%