2020
DOI: 10.5114/wo.2020.93677
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of the nonradioactive inducible magnetic seed system Magseed for preoperative localization of nonpalpable breast lesions – initial clinical experience

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
11
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(12 citation statements)
references
References 23 publications
1
11
0
Order By: Relevance
“…The study design of the included studies was prevalently prospective (18, 66,7%), involving from 4 to 320 patients each. The devices used in the studies were: SAVI SCOUT (9, 33.3%) [ [32] , [33] , [34] , [35] , [36] , [37] , [38] , [39] , [40] , [41] ], Magseed (10, 37%) [ 38 , [42] , [43] , [44] , [45] , [46] , [47] , [48] , [49] , [50] ], Localizer (5, 18.5%) [ 38 , 40 , [51] , [52] , [53] , [54] , [55] ] and MaMaLoc (1, 3.7%) [ 56 ]. One study reported results about the use of both Magseed and LOCalizer [ 38 ] and in one both SAVI SCOUT and LOCalizer were used [ 40 ].…”
Section: Resultsmentioning
confidence: 99%
“…The study design of the included studies was prevalently prospective (18, 66,7%), involving from 4 to 320 patients each. The devices used in the studies were: SAVI SCOUT (9, 33.3%) [ [32] , [33] , [34] , [35] , [36] , [37] , [38] , [39] , [40] , [41] ], Magseed (10, 37%) [ 38 , [42] , [43] , [44] , [45] , [46] , [47] , [48] , [49] , [50] ], Localizer (5, 18.5%) [ 38 , 40 , [51] , [52] , [53] , [54] , [55] ] and MaMaLoc (1, 3.7%) [ 56 ]. One study reported results about the use of both Magseed and LOCalizer [ 38 ] and in one both SAVI SCOUT and LOCalizer were used [ 40 ].…”
Section: Resultsmentioning
confidence: 99%
“…Magseed is based on the detection of a ferromagnetic seed by a proprietary handheld magnetometer called Sentimag which was originally developed for sentinel lymph node and occult breast lesion localisation in the MagSNOLL trial [ 32 , 33 ]. For the purpose of occult breast lesion localisation, a 5 mm seed is implanted using an 18 G introducer.…”
Section: Discussionmentioning
confidence: 99%
“…These techniques also utilise the gamma probe which is routinely available for sentinel lymph node biopsies, therefore avoiding purchase of additional equipment. However, radioactive localisation techniques are limited by the availability of nuclear medicine services, which may preclude regional/rural centres and are under strict government regulations, 6,8,13–17 which can be cumbersome and prescriptive.…”
Section: Introductionmentioning
confidence: 99%