Evaluation of the Penàz servo-plethysmo-manometer for the continuous, non-invasive measurement of finger blood pressure

Abstract: Blood pressure in the finger was measured by a servo-plethysmomanometer constructed after the design of Penàz, which uses the principle of the unloaded arterial wall. The device contains a photoelectric plethysmograph mounted in an inflatable cuff and an electro-pneumatic transducer to control air pressure in the cuff via a servosystem. Comparison of simultaneous measurements of intra-arterial pressure in the brachial artery was performed on 33 patients suspected of having hypertension. In 12 patients evaluati… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
51
0
2

Year Published

1986
1986
1998
1998

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 129 publications
(55 citation statements)
references
References 8 publications
2
51
0
2
Order By: Relevance
“…This is surprising as it is generally accepted that amplification of the systolic BP occurs distally, due to a combination of physiological events including waveform dispersion and reflection. 11,12,33 We have previously noted 23 that the bulk of validation studies on the Finapres suggested that the systolic and diastolic pressures were underrecorded compared with that directly assessed; 3,14,18,24,26,28 physiologically one would expect an accurate peripheral device to record a higher systolic but a lower diastolic pressure compared with that recorded at a more proximal recording site. However, the extent to which the systolic pressure is amplified may be variable, depending both on biological (age and extent of arterial pathology) and technical factors.…”
Section: Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…This is surprising as it is generally accepted that amplification of the systolic BP occurs distally, due to a combination of physiological events including waveform dispersion and reflection. 11,12,33 We have previously noted 23 that the bulk of validation studies on the Finapres suggested that the systolic and diastolic pressures were underrecorded compared with that directly assessed; 3,14,18,24,26,28 physiologically one would expect an accurate peripheral device to record a higher systolic but a lower diastolic pressure compared with that recorded at a more proximal recording site. However, the extent to which the systolic pressure is amplified may be variable, depending both on biological (age and extent of arterial pathology) and technical factors.…”
Section: Discussionmentioning
confidence: 99%
“…The BP, meas-ured at the digit using servo-plethysmomanometry, employs the volume clamp technique. 2,3 The finger artery is unloaded such that its arterial volume is held constant (or clamped) at any given instant. A servo-controller compares the arterial diameter with a reference value (the set point) that has been chosen to ensure a near-zero transmural digital artery presure.…”
Section: Finapres 2300 Non-invasive Monitormentioning
confidence: 99%
See 3 more Smart Citations