2022
DOI: 10.3138/jammi-2021-0026
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of the performance of multiple immunoassay diagnostic platforms on the National Microbiology Laboratory SARS-CoV-2 National Serology Panel

Abstract: BACKGROUND: Serological assays designed to detect SARS-CoV-2 antibodies are being used in serological surveys and other specialized applications. As a result, and to ensure that the outcomes of serological testing meet high quality standards, evaluations are required to assess the performance of these assays and the proficiency of laboratories performing them. METHODS: A panel of 60 plasma/serum samples from blood donors who had Real Time-Polymerase Chain Reaction (RT-PCR) confirmed SARS-CoV-2 infections and 2… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 26 publications
0
2
0
Order By: Relevance
“…Seropositivity was defined as an OD 490 ratio greater than one with the experimentally determined cut-off, which corresponds to the mean of 10 negative controls plus three times the standard deviation of the negative controls for each experiment. This anti-RBD IgG ELISA was validated on the Canadian National Microbiology Laboratory SARS-CoV-2 National Serology Panel (23,26). Absence of previous infection to SARS-CoV-2 was confirmed in the naïve cohort by performing an ELISA detecting specific IgG antibodies for the Nucleoprotein (anti-N) of SARS-CoV-2 and the anti-RBD ELISA before vaccination.…”
Section: Enzyme-linked Immunosorbent Assaymentioning
confidence: 99%
“…Seropositivity was defined as an OD 490 ratio greater than one with the experimentally determined cut-off, which corresponds to the mean of 10 negative controls plus three times the standard deviation of the negative controls for each experiment. This anti-RBD IgG ELISA was validated on the Canadian National Microbiology Laboratory SARS-CoV-2 National Serology Panel (23,26). Absence of previous infection to SARS-CoV-2 was confirmed in the naïve cohort by performing an ELISA detecting specific IgG antibodies for the Nucleoprotein (anti-N) of SARS-CoV-2 and the anti-RBD ELISA before vaccination.…”
Section: Enzyme-linked Immunosorbent Assaymentioning
confidence: 99%
“…The COVID-19 pandemic has impacted on all elements of society. Blood operators have played an important role in studying and characterizing the COVID-19 pandemic and can provide lessons learned from this experience [ 10 , 11 , 12 , 13 , 14 ].…”
Section: Introductionmentioning
confidence: 99%