2022
DOI: 10.1016/j.epsr.2022.108701
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of the power frequency magnetic field generated by three-core armored cables through 3D finite element simulations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 20 publications
2
3
0
Order By: Relevance
“…The obtained curve is more illustrative of the distribution of the magnetic induction intensity inside the cable, as shown in Figure 3. Research on the simulation and analysis of the magnetic field of cables already exists, and simulation result patterns are consistent with this paper, which qualitatively verifies the accuracy of the simulation in this paper [20][21][22].…”
Section: The Magnetic Field Of Cable Accessories In Good Conditionsupporting
confidence: 87%
See 1 more Smart Citation
“…The obtained curve is more illustrative of the distribution of the magnetic induction intensity inside the cable, as shown in Figure 3. Research on the simulation and analysis of the magnetic field of cables already exists, and simulation result patterns are consistent with this paper, which qualitatively verifies the accuracy of the simulation in this paper [20][21][22].…”
Section: The Magnetic Field Of Cable Accessories In Good Conditionsupporting
confidence: 87%
“…The simulation of the magnetic field of the cable in the presence of water droplets and the magnetic field distribution at t = 15 ms for different defect degrees are shown in Figures 4 and 5. this paper, which qualitatively verifies the accuracy of the simulation in this paper [20][21][22].…”
Section: Effect Of Water Droplet Defects On the Magnetic Fluxsupporting
confidence: 80%
“…In addition, the 3-phase cables are helically twisted which reduces the magnetic field level as the fields of the three cores party cancel each other out. This cancellation could not be taken into account in the model, as it would require information on the twist length periodicity (the cores have made a 360° twist around each other), which is currently not provided in cable specifications [82]. For bundled DC cables the orientation in which the cables are placed on/in the seabed (vertical, horizonal or diagonal) influences the interaction with the geomagnetic field.…”
Section: Comparing Measured and Modelled Emf Levelsmentioning
confidence: 99%
“…Andrew summarized the electric and magnetic fields generated by cables in offshore wind farms, quantifying them through the finite element method (FEM), indicating that cables with excellent shielding properties do not directly produce electric fields outside the cable, yet they induce magnetic fields in the external environment [11]. Del-Pino-López utilized an ultra-shortened 3D-FEM model to investigate the magnetic field around such cables, offering insights into how cable material and design influence magnetic fields and proposing optimized designs [12]. Another issue that needs to be addressed urgently is temperature.…”
Section: Introductionmentioning
confidence: 99%