2021
DOI: 10.1109/tdei.2021.009636
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of the Properties of Mixtures of Aromatic Mineral Oil and Synthetic Ester for High-Voltage Equipment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(4 citation statements)
references
References 20 publications
0
4
0
Order By: Relevance
“…This paper puts forward the detection technology of high-voltage electrical equipment, that is, during the AC withstand voltage test of high-voltage cable, measure the partial discharge at multiple positions of high-voltage cable synchronously, identify the small defects caused by the construction damage of high-voltage cable and the poor installation of accessories through the PDD at multiple positions, improve the completion acceptance test method of high-voltage cable, and reduce the hidden danger operation risk of high-voltage cable. It is verified that the application of AI in PDD of high-voltage electrical equipment can effectively improve the fault detection rate of high-voltage cable completion acceptance and reduce the hidden dangers of high-voltage cable belt [6] [9].…”
Section: Introductionmentioning
confidence: 86%
See 1 more Smart Citation
“…This paper puts forward the detection technology of high-voltage electrical equipment, that is, during the AC withstand voltage test of high-voltage cable, measure the partial discharge at multiple positions of high-voltage cable synchronously, identify the small defects caused by the construction damage of high-voltage cable and the poor installation of accessories through the PDD at multiple positions, improve the completion acceptance test method of high-voltage cable, and reduce the hidden danger operation risk of high-voltage cable. It is verified that the application of AI in PDD of high-voltage electrical equipment can effectively improve the fault detection rate of high-voltage cable completion acceptance and reduce the hidden dangers of high-voltage cable belt [6] [9].…”
Section: Introductionmentioning
confidence: 86%
“…When using ultrasonic method to detect partial discharge, because corona defect and free metal particle defect are very different from the characteristics of general partial discharge signal, the atlas of corona discharge and metal particle discharge are analyzed separately. When using ultrasonic method to detect partial discharge, it is necessary to determine the background signal [7] [9].…”
Section: Characteristics Of Partial Discharge Under Ultrasonic Testingmentioning
confidence: 99%
“…Moreover, the ionic compounds in the aged oil may be dissolved in NEO because of their polar nature; in addition, when the percentage of NEO is increased, this effect becomes prevalent. The increasing dissipation factor of the mixed oil may be due to the aged MO containing a high quantity of polar colloidal components and odorous hydrocarbons [ 37 ].…”
Section: Physical Mechanismsmentioning
confidence: 99%
“…According to [5], natural esters are miscible with mineral oil in all proportions. The mixtures themselves are also becoming widely acceptable since the price of esters is several times higher than the price of mineral oil [30]. A dielectric liquid can be obtained using mixtures of mineral oil with natural esters as the resultant, which is characterized by better fire properties (flash point, fire point), a higher degree of biodegradation and an increased water solubility limit compared to pure mineral oil [31,32].…”
Section: Introductionmentioning
confidence: 99%