2016
DOI: 10.1016/j.cca.2016.02.016
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of the SediMax automated microscopy sediment analyzer and the Sysmex UF-1000i flow cytometer as screening tools to rule out negative urinary tract infections

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
25
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 33 publications
(25 citation statements)
references
References 28 publications
0
25
0
Order By: Relevance
“…Flow cytometry systems, such as the FDA-approved UF-1000i (Sysmex), use a combination of light scattering and fluorescence to rapidly screen for the presence of bacteria in urine 4547 . Flow cytometry is a good system for selecting samples for further analysis, and has been used to identify pathogen-positive urine for further complex testing, such as mass spectrometry analysis.…”
Section: Detecting Utismentioning
confidence: 99%
“…Flow cytometry systems, such as the FDA-approved UF-1000i (Sysmex), use a combination of light scattering and fluorescence to rapidly screen for the presence of bacteria in urine 4547 . Flow cytometry is a good system for selecting samples for further analysis, and has been used to identify pathogen-positive urine for further complex testing, such as mass spectrometry analysis.…”
Section: Detecting Utismentioning
confidence: 99%
“…Diverse papers have shown that the use of FCA reduces the number of processed negative urinary specimens. Authors demonstrate variably reduction in bacterial culture ranging from 28% to 60% [ 14 , 22 , 24 26 , 29 33 , 50 ]…”
Section: Studiesmentioning
confidence: 99%
“…If confirmed in studies with larges series, the UFC screening method would be more efficient when both bacterial and leukocyte counts were detected. Various authors demonstrate that this implies an increase in the sensitivity of the technique [ 24 , 29 , 33 , 35 , 49 ]. In contrast to these findings, other studies do show no benefit when combining the use of both counts for UTI screening [ 14 , 26 , 30 ].…”
Section: Studiesmentioning
confidence: 99%
“…PPV of the FUS-200 for RBC and WBC were worse than that was reported by Ince et al 15 and similar to PPV reported by Yuksel et al 10 . These results could be due to urine centrifugation procedure before analysis that may form aggregates or produce cell lysis 27 . The NPV s of the devices were similar or better than their PPVs.…”
Section: Discussionmentioning