2022
DOI: 10.1016/j.wneu.2021.10.164
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of the Stability of a Novel Lateral Plate Internal Fixation: An In Vitro Biomechanical Study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 31 publications
0
4
0
Order By: Relevance
“…Therefore, this is consistent with broken nails caused by stress fatigue in some patients after long-term activity. [37][38][39] This experiment verified that the pedicle screw internal fixation system has an obvious effect on the lumbar spine and that role in maintaining stability can reduce the probability of spinal instability. In this experiment, both models produced stress concentration at the root of the screw and the connection of the screw rod, which is consistent with the position of internal fixation failure and fracture commonly observed in the clinic.…”
Section: Discussionmentioning
confidence: 56%
See 1 more Smart Citation
“…Therefore, this is consistent with broken nails caused by stress fatigue in some patients after long-term activity. [37][38][39] This experiment verified that the pedicle screw internal fixation system has an obvious effect on the lumbar spine and that role in maintaining stability can reduce the probability of spinal instability. In this experiment, both models produced stress concentration at the root of the screw and the connection of the screw rod, which is consistent with the position of internal fixation failure and fracture commonly observed in the clinic.…”
Section: Discussionmentioning
confidence: 56%
“…Therefore, this is consistent with broken nails caused by stress fatigue in some patients after long-term activity. [37–39]…”
Section: Discussionmentioning
confidence: 99%
“…Selection of either posterior or lateral fixation as a supplementary procedure in OLIF surgery has long been disputed. Theoretically, many FE and in vitro studies have shown that the traditional gold standard bipedicle fixation and other kinds of posterior fixation systems indeed provide more stability for the lumbar spine after OLIF surgery than lateral fixation systems (30,42,58,59). However, practically, posterior supplementary instrumentation (1) involves additional use of the prone posture, extra incisions, more blood loss and surgery time and (2) is detrimental to the integrity of the posterior column.…”
Section: Discussionmentioning
confidence: 99%
“…Several previous studies have reported the use of plate and screw fixation systems for OLIF and have demonstrated the biomechanical efficiency of the system (7,8). However, these studies have two noteworthy limitations and could be further improved.…”
Section: Currently Clinicians Mainly Adopt Two Surgicalmentioning
confidence: 99%