Evaluation of the stiffness characteristics of square pore CoCrMo cellular structures manufactured using laser melting technology for potential orthopaedic applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

5
79
0
1

Year Published

2015
2015
2023
2023

Publication Types

Select...
5
3
1

Relationship

0
9

Authors

Journals

citations
Cited by 103 publications
(85 citation statements)
references
References 21 publications
5
79
0
1
Order By: Relevance
“…However, due to the high stiffness of CoCr, stress shielding and bone resorption have been a concern. Constructing a open cellular structure has been proved to lower the stiffness of CoCr and provide better match with the human bones [84,85]. Customized open cellular CoCr strctures have been successfully manufactured with EBM for load-bearing applications with comparable biological response of Ti6Al4V [86].…”
Section: Materials Manufactured With Ebmmentioning
confidence: 99%
“…However, due to the high stiffness of CoCr, stress shielding and bone resorption have been a concern. Constructing a open cellular structure has been proved to lower the stiffness of CoCr and provide better match with the human bones [84,85]. Customized open cellular CoCr strctures have been successfully manufactured with EBM for load-bearing applications with comparable biological response of Ti6Al4V [86].…”
Section: Materials Manufactured With Ebmmentioning
confidence: 99%
“…Other methods, in particular, electron beam melting (EBM), are widely used in addition to selective laser melting (SLM). Their suitability for the manufacture of components for applications with a bio-medical background has in many cases been confirmed [1][2][3].…”
Section: Introductionmentioning
confidence: 99%
“…In order to reduce the risk of stress shielding, metal alloy implant components can be fabricated for instance with open-porous structures that provide an elastic modulus low enough for this specification [9][10][11][12][13][14]. Open porous structures were generated and tested as irregular [15][16][17][18] and regular or non-stochastic scaffolds [9,10,[19][20][21][22][23][24][25][26]. Since trabecular bone is irregular, irregular structures may be a more authentic imitation than regular ones.…”
Section: Introductionmentioning
confidence: 99%
“…Additive manufacturing (AM) methods, such as selective laser melting (SLM), are widely used for fabricating open-porous metals and alloys [22,25,27]. They afford the means for the development and manufacturing of structures with defined mechanical and geometrical properties, e.g., with an elastic modulus in the range of that of human bone [4,[28][29][30].…”
Section: Introductionmentioning
confidence: 99%