2013
DOI: 10.1128/jcm.00831-13
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of the Verigene Gram-Positive Blood Culture Nucleic Acid Test for Rapid Detection of Bacteria and Resistance Determinants

Abstract: (2) and is associated with prolonged hospitalization, with higher health care costs (3). The clinical microbiology laboratory plays a vital role in the treatment of patients with bloodstream infections. While current methods for the detection and characterization of bloodstream pathogens can take days, the risk of death from sepsis increases by 6 to 10% per hour from the onset of shock to the start of effective antimicrobial treatment (4).Over 50% of organisms identified in positive blood cultures are Gram-pos… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

14
74
1
1

Year Published

2015
2015
2023
2023

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 117 publications
(90 citation statements)
references
References 13 publications
14
74
1
1
Order By: Relevance
“…The gold standard method for pathogen identification in BSI, used also in our laboratory, requires culturing patient blood in an automated continuous monitoring system, resulted as "not detected" which is three times less, compared with the data, obtained in our hands (4). In regards to the oxacillin resistance, Verigene mecA detection and Vitek-2 correlation was reported to be 97-100% [7,8], which is differs from the results obtained in our study, 75.7%.…”
Section: For Example In 2013 In the Military Medicalcontrasting
confidence: 91%
See 1 more Smart Citation
“…The gold standard method for pathogen identification in BSI, used also in our laboratory, requires culturing patient blood in an automated continuous monitoring system, resulted as "not detected" which is three times less, compared with the data, obtained in our hands (4). In regards to the oxacillin resistance, Verigene mecA detection and Vitek-2 correlation was reported to be 97-100% [7,8], which is differs from the results obtained in our study, 75.7%.…”
Section: For Example In 2013 In the Military Medicalcontrasting
confidence: 91%
“…FISH (fluorescent in situ hybridization), PCR, MALDI-TOF and sequencing have been implemented for more than a decade [3][4][5][6]. Micro-array panels for BSI investigation have been recently developed to identify various Gram-positive, Gram-negative and antibiotic resistance targets in blood cultures [5,[7][8][9].…”
Section: Introductionmentioning
confidence: 99%
“…Several clinically approved nanomedicines and nanoformulations have made the transition from bench to bedside, 34 including, for example, Verigene ® , a nanodiagnostic platform for the rapid identification of a range of infectious pathogens. [35][36][37][38] In Europe, numerous examples may be noted of commercially available nanotherapeutic products for oral and parenteral administration, respectively.…”
Section: What Is Nanomedicine?mentioning
confidence: 99%
“…For example, a major strength of BC-GP is the ability to differentiate several species of Staphylococcus, as well as the mecA gene. 82,85 Verigene ® is limited to identifying certain species of fungi and Gramnegative bacteria. 83 Another weakness is the lack of published cost-effectiveness analyses.…”
mentioning
confidence: 99%
“…83 Another weakness is the lack of published cost-effectiveness analyses. 85 The BC-GN and BC-GP are reliable, accurate, and rapid assays, which can be integrated into the routine workflow of a microbiology laboratory, even if their clinical benefits should be further evaluated.…”
mentioning
confidence: 99%