2019
DOI: 10.1007/s00256-019-03339-1
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of ulnar variance on wrist MR imaging: is it a reliable measure?

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 13 publications
0
5
0
Order By: Relevance
“…Previously, these values were found as good to excellent in various studies using radiographs for both inter- and intra-observer reliabilities, with an intraclass coefficient range of 0.82–0.93 for inter-observer and an intraclass correlation coefficient (ICC) of 0.931 for intra-observer reliability (4,4144). In a study conducted using MRI, ICCs for inter- and intra-observer reliability were 0.857 and 0.915, respectively (4). In another study involving pediatric population, ICC values were 0.88–0.92 for intra-observer reliability and 0.75 for inter-observer reliability (5,45).…”
Section: Discussionmentioning
confidence: 90%
See 3 more Smart Citations
“…Previously, these values were found as good to excellent in various studies using radiographs for both inter- and intra-observer reliabilities, with an intraclass coefficient range of 0.82–0.93 for inter-observer and an intraclass correlation coefficient (ICC) of 0.931 for intra-observer reliability (4,4144). In a study conducted using MRI, ICCs for inter- and intra-observer reliability were 0.857 and 0.915, respectively (4). In another study involving pediatric population, ICC values were 0.88–0.92 for intra-observer reliability and 0.75 for inter-observer reliability (5,45).…”
Section: Discussionmentioning
confidence: 90%
“…Our inter-and intra-observer agreement values for UV measurement on coronal CT slices using the perpendicularis technique were excellent. Previously, these values were found as good to excellent in various studies using radiographs for both inter-and intra-observer reliabilities, with an intraclass coefficient range of 0.82-0.93 for inter-observer and an intraclass correlation coefficient (ICC) of 0.931 for intra-observer reliability (4,(41)(42)(43)(44). In a study conducted using MRI, ICCs for inter-and intra-observer reliability were 0.857 and 0.915, respectively (4).…”
Section: Discussionmentioning
confidence: 91%
See 2 more Smart Citations
“…In the coronal view of the PD-FS sequence, three consecutive slices were selected in which the whole TFCC, including the radial and ulnar insertion, could be visualized best. According to Yoshioka’s method, the disc thickness and ulnar variance were measured in these slices, and the mean value was calculated (Serfaty et al., 2020; Yoshioka et al., 2007). When there was a complete and large perforation, the disc thickness was not measurable and was recorded as zero.…”
Section: Methodsmentioning
confidence: 99%