2015
DOI: 10.1152/ajprenal.00072.2015
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of voiding assays in mice: impact of genetic strains and sex

Abstract: Void spot assays (VSA) and cystometry are two of the most common tests performed in mice to assess lower urinary tract function. Assay protocols and methodology vary greatly among laboratories, and little is known about reproducibility of results generated by different laboratories. We performed VSA in four mouse strains, comparing males with females and comparing results between two independent laboratories. Unique aspects of the current study include direct comparison of results of VSA performed in a similar… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

3
73
1

Year Published

2018
2018
2023
2023

Publication Types

Select...
4
1
1

Relationship

3
3

Authors

Journals

citations
Cited by 56 publications
(77 citation statements)
references
References 35 publications
3
73
1
Order By: Relevance
“…Individual void spots were counted and their areas were measured using ImageJ (NIH, Bethesda, MD). Bright spots smaller than 0.06 cm 2 were eliminated to account for grid "spray" and nonurine particles . The VSA parameters measured were: the number of voids, the total void area, the average area per void, and the area of the primary (largest) void.…”
Section: Methodsmentioning
confidence: 99%
“…Individual void spots were counted and their areas were measured using ImageJ (NIH, Bethesda, MD). Bright spots smaller than 0.06 cm 2 were eliminated to account for grid "spray" and nonurine particles . The VSA parameters measured were: the number of voids, the total void area, the average area per void, and the area of the primary (largest) void.…”
Section: Methodsmentioning
confidence: 99%
“…Cystometry was performed with minimal alterations to previously published protocols. 31, 32 Mice were anesthetized with urethane (1.43 g/kg sc). Thirty minutes after urethane dosing, an incision was made in the ventral abdomen to expose the bladder.…”
Section: Methodsmentioning
confidence: 99%
“…Total urine spots on filter paper were subsequently visualized under UV light and digitally photographed. Images were converted to black and white, and quantitation was performed with ImageJ software . VSA were performed at the time points depicted in Figure .…”
Section: Methodsmentioning
confidence: 99%
“…Images were converted to black and white, and quantitation was performed with ImageJ software. 7 VSA were performed at the time points depicted in Figure 1.…”
Section: Voiding Spot Assays (Vsa)mentioning
confidence: 99%
See 1 more Smart Citation