2016
DOI: 10.1016/j.vacuum.2016.07.030
|View full text |Cite
|
Sign up to set email alerts
|

Evaporation factor in productivity increase of hot target magnetron sputtering systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
16
1
1

Year Published

2016
2016
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 39 publications
(19 citation statements)
references
References 17 publications
1
16
1
1
Order By: Relevance
“…Our previous studies show that this value is almost the same as the power density of the ion flux bombarding the surface of the target, i.e. W ion [14]. The variation of W ion in time is defined by the power oscillogram of the magnetron energy supply.…”
Section: No /mentioning
confidence: 93%
“…Our previous studies show that this value is almost the same as the power density of the ion flux bombarding the surface of the target, i.e. W ion [14]. The variation of W ion in time is defined by the power oscillogram of the magnetron energy supply.…”
Section: No /mentioning
confidence: 93%
“…Нагрев вызывается воздействием ионного потока, бомбардирующего мишень при магнетронном распылении. Схожий эффект описан в [51]. Для его реализации в случае металлических мишеней поток тепла уменьшают, изолируя их от охлаждаемых магнитов магнетронной системы.…”
Section: обсуждение результатовunclassified
“…13 ∼1.4 W/cm 2 (pulsed discharge) 0.5 Pa (∼10 sccm) Posadowski (WMK-50) 14 ≤ 300 W/cm 2 (pulsed discharge) ∼0.25 Pa Bleykher et.al. 15 1-8 W/cm 2 (period averaged value, pulsed discharge) 0. power density of the M3C is sufficiently low compared with previous film production studies using DC discharges. [10][11][12] In general, pulsed discharge techniques are useful for low gas pressure operation of less than 0.5 Pa. [13][14][15] Plasma confinement by a magnetic mirror enables DC sputtering with low power density, in spite of low gas pressure of less than 0.5 Pa. Figure 3 shows the dependence of the plasma discharge light emission pattern on p Ar and P DC .…”
Section: Power Densitymentioning
confidence: 99%
“…15 1-8 W/cm 2 (period averaged value, pulsed discharge) 0. power density of the M3C is sufficiently low compared with previous film production studies using DC discharges. [10][11][12] In general, pulsed discharge techniques are useful for low gas pressure operation of less than 0.5 Pa. [13][14][15] Plasma confinement by a magnetic mirror enables DC sputtering with low power density, in spite of low gas pressure of less than 0.5 Pa. Figure 3 shows the dependence of the plasma discharge light emission pattern on p Ar and P DC . Low power density operation of 0.25 W/cm 2 was confirmed under experimental conditions of p Ar = 0.26 Pa and P DC = 5 W. Although the emission intensity increases with the increasing p Ar , the doughnut-shaped plasma discharge region narrows.…”
Section: Power Densitymentioning
confidence: 99%