2014
DOI: 10.1134/s0869864314020127
|View full text |Cite
|
Sign up to set email alerts
|

Evaporation of two liquid droplets moving sequentially through high-temperature combustion products

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

3
57
0
2

Year Published

2015
2015
2017
2017

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 38 publications
(62 citation statements)
references
References 4 publications
3
57
0
2
Order By: Relevance
“…1 was similar to facilities that we used in our previous studies [7][8][9], but it was equipped with a number of specific tools for experiments. The main elements of the setup are: motorized pointing devices 8 with controlled rate and the ability to install remote control cameras, a device for the sequential supply of water droplets 11 with an adjustable distance between droplets released from it, high-speed video cameras 1 "Phantom V411" and "Phantom Miro M310" with a maximum frame frequency up to 6·10 5 fps, a laboratory microbalance 6 "ViBRA HT 84RCE" with a resolution 10 -5 g, an electronic single-channel pipette "Finnpipette Novus" 5 (functional range from 10 ȝL to 100 ȝL, increments -0.1 ȝL), a workstation 3 for data processing and the analysis of results.…”
Section: Experimental Setup and Proceduresmentioning
confidence: 99%
See 1 more Smart Citation
“…1 was similar to facilities that we used in our previous studies [7][8][9], but it was equipped with a number of specific tools for experiments. The main elements of the setup are: motorized pointing devices 8 with controlled rate and the ability to install remote control cameras, a device for the sequential supply of water droplets 11 with an adjustable distance between droplets released from it, high-speed video cameras 1 "Phantom V411" and "Phantom Miro M310" with a maximum frame frequency up to 6·10 5 fps, a laboratory microbalance 6 "ViBRA HT 84RCE" with a resolution 10 -5 g, an electronic single-channel pipette "Finnpipette Novus" 5 (functional range from 10 ȝL to 100 ȝL, increments -0.1 ȝL), a workstation 3 for data processing and the analysis of results.…”
Section: Experimental Setup and Proceduresmentioning
confidence: 99%
“…Works [7][8][9] perform the results of experimental studies, illustrating the necessary and sufficient conditions for the entrainment of water droplets by high-temperature gases. Studies [7][8][9] demonstrated that droplets with a size less than 200 ȝm are almost completely carried away by typical combustion products. This occurs under conditions corresponding to the systems of thermal water treatment [1][2][3] and polydisperse extinguishing [4][5][6].…”
Section: Introductionmentioning
confidence: 99%
“…Figure 1 shows the scheme of a setup used in our experiments. Registration tools were similar to facilities that we used in works [7][8][9]. There are two high-speed (up to 10 5 fps) cameras in our setup: "Phantom V411" and "Phantom Miro M310".…”
Section: Introductionmentioning
confidence: 99%
“…There are two high-speed (up to 10 5 fps) cameras in our setup: "Phantom V411" and "Phantom Miro M310". In contrast to our previous experiments [7][8][9], we used software "Tema Automotive" [10,11] for data processing from video recordings. With the help of this software we could observe a continuously moving water bomb or individual droplets.…”
Section: Introductionmentioning
confidence: 99%
“…Front the camera sets the diffusion screen 24 connected to the laser light guide 18 (installation height of the laser in this case is not important) for SP methodology in [6]. All captured video passed on to a workstation, where performed their processing and determination of the required parameters with the help of specialized software "Tema Automotive" [7].…”
Section: Introductionmentioning
confidence: 99%