Evidence for Contamination of Silica Microparticles in Advanced Platelet-Rich Fibrin Matrices Prepared Using Silica-Coated Plastic Tubes

Abstract: Platelet-rich fibrin (PRF) therapy has been widely applied in regenerative dentistry, and PRF preparation has been optimized to efficiently form fibrin clots using plain glass tubes. Currently, a shortage of commercially available glass tubes has forced PRF users to utilize silica-coated plastic tubes. However, most plastic tubes are approved by regulatory authorities only for diagnostic use and remain to be approved for PRF therapy. To clarify this issue, we quantified silica microparticles incorporated into … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
44
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 32 publications
(51 citation statements)
references
References 23 publications
2
44
0
Order By: Relevance
“…In comparison with the negative control, Cytrans Granules, silica microparticles derived from Neotube and Vacuette significantly reduced cell viability at the dilution of 1:32 and 1:16, respectively. Since Venoject II contains fewer silica microparticles per tube [2], its silica particles exerted growth inhibitory effects at lower dilutions (1:4 and lower). However, when not diluted, all the silica microparticles substantially inhibited growth.…”
Section: Resultsmentioning
confidence: 99%
See 4 more Smart Citations
“…In comparison with the negative control, Cytrans Granules, silica microparticles derived from Neotube and Vacuette significantly reduced cell viability at the dilution of 1:32 and 1:16, respectively. Since Venoject II contains fewer silica microparticles per tube [2], its silica particles exerted growth inhibitory effects at lower dilutions (1:4 and lower). However, when not diluted, all the silica microparticles substantially inhibited growth.…”
Section: Resultsmentioning
confidence: 99%
“…Based on the previous findings [2], the sizes of silica microparticles in individual tubes are roughly determined. Neotube: several microns to 40 μm, Vacuette: submicrons to 20 μm, Venoject II: submicrons to 6 μm.…”
Section: Preparation Of Suspension Of Silica Microparticlesmentioning
confidence: 99%
See 3 more Smart Citations