Evidence for growth inhibition by platinum electrodes at low current levels

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
9
0

Year Published

1996
1996
2010
2010

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 16 publications
(9 citation statements)
references
References 9 publications
0
9
0
Order By: Relevance
“…38 7. No effect of the nature of metallic electrodes was found on the tumor destruction, 7,38,39 e.g., silver and tungsten electrodes gave results similar to platinum: 7 this also means that a slight anodic dissolution of platinum that might occur during the ECT experiment is not responsible for the necrosis of the tumor. 7 8.…”
Section: Phenomenology Of Ectmentioning
confidence: 58%
See 1 more Smart Citation
“…38 7. No effect of the nature of metallic electrodes was found on the tumor destruction, 7,38,39 e.g., silver and tungsten electrodes gave results similar to platinum: 7 this also means that a slight anodic dissolution of platinum that might occur during the ECT experiment is not responsible for the necrosis of the tumor. 7 8.…”
Section: Phenomenology Of Ectmentioning
confidence: 58%
“…This work of Miklav i and coworkers also confirms the lack of any role of the nature of electrodes (e.g., Pt, Ir, Au, Ti) or hyperthermia in the destruction of the tumor tissue, mentioned above from the work of other investigators. 7,38,39 9. Many workers report that fast-growing regions of organisms, i.e., tumors are electrically negative with respective to the surrounding normal tissue.…”
Section: Phenomenology Of Ectmentioning
confidence: 98%
“…platinum chloride compounds from electrode corrosion dissolve at higher potentials and can inhibit cell growth [45], however at lower potentials and in the presence of serum albumin no platinum dissolution was observed [46]. On the other hand, the platinum corrosion can probably be ruled out in this case, since a similar growth inhibiting effect at low currents was also observed on indium tin oxide electrodes.…”
Section: In Vitro Experimentsmentioning
confidence: 71%
“…This was probably because the local environment around the electrodes is sterilized during treatment by the cytotoxic electrode products. Platinum salts, leached from the electrodes during treatment may also augment this effect as they are strongly bactericidal even in low concentrations [27,28]. This contributes to the extremely low long-term morbidity associated with electrolysis and suggests that there are unlikely to be any major mid-or long-term complications in the clinical setting.…”
Section: Discussionmentioning
confidence: 93%