2015
DOI: 10.1016/j.radmeas.2015.05.009
|View full text |Cite
|
Sign up to set email alerts
|

Evidence of shallow TL peak contributions in infrared radiofluorescence

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
1

Year Published

2015
2015
2025
2025

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 10 publications
(14 citation statements)
references
References 11 publications
0
13
1
Order By: Relevance
“…These results suggest that the given dose can be recovered with sufficient accuracy using the experimental conditions in our IRSAR procedure (Table S1) We also tested the RF 70 procedure (Frouin et al, 2017) on our samples. Preliminary tests showed that IR-RF measurements made at 70°C did not improve the shapes of the decay curves for our samples, in contrast to the findings of Huot et al (2015) and Frouin et al (2017). Nevertheless, the RF 70 procedure yields slightly different results to those obtained using the IRSAR procedure: the RF 70 signal intensity is higher and the calculated D e values differ by 11-65 Gy, with the RF 70 values being larger in some instances and smaller in others (Table 1); two examples are shown in Fig.…”
Section: Multi-grain Ir-rfcontrasting
confidence: 89%
“…These results suggest that the given dose can be recovered with sufficient accuracy using the experimental conditions in our IRSAR procedure (Table S1) We also tested the RF 70 procedure (Frouin et al, 2017) on our samples. Preliminary tests showed that IR-RF measurements made at 70°C did not improve the shapes of the decay curves for our samples, in contrast to the findings of Huot et al (2015) and Frouin et al (2017). Nevertheless, the RF 70 procedure yields slightly different results to those obtained using the IRSAR procedure: the RF 70 signal intensity is higher and the calculated D e values differ by 11-65 Gy, with the RF 70 values being larger in some instances and smaller in others (Table 1); two examples are shown in Fig.…”
Section: Multi-grain Ir-rfcontrasting
confidence: 89%
“…The technique was introduced by Trautmann et al . 55 and Erfurt & Krbetschek 20 and a reinvestigation of the IR-RF signal characteristics recently led to an improved measurement protocol, which requires keeping the temperature constant at 70 °C during measurement 21 , 56 , 57 .…”
Section: Methodsmentioning
confidence: 99%
“…Alternatively, thermal assistance for electron eviction could be another factor, since it has long been argued that the IRSL luminescence emission is assisted by temperature (Hütt et al, 1988). In addition, we have noticed that the solar simulator of the Lexsyg device increases the temperature of the disk during bleaching (Huot et al, 2015). Thermal assistance, because of a temperature increased during bleaching, would nicely explain the apparent delay in bleaching.…”
Section: Efficiency Of Wavelengthsmentioning
confidence: 85%
“…Only after having sufficiently emptied the dosimetric trap would the overall probability of electron trapping increases again. Evidence for a shallow trap contributing to the luminescence at 865 nm in feldspars is presented by Huot et al (2015).…”
Section: Efficiency Of Wavelengthsmentioning
confidence: 98%
See 1 more Smart Citation