ExacTrac X-ray 6 degree-of-freedom image-guidance for intracranial non-invasive stereotactic radiotherapy: Comparison with kilo-voltage cone-beam CT

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
72
2

Year Published

2011
2011
2020
2020

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 81 publications
(77 citation statements)
references
References 22 publications
3
72
2
Order By: Relevance
“…Several groups have evaluated positioning accuracies of independent IGRT methodologies utilizing floor mounted stereotactic X‐ray localization and gantry‐mounted volumetric (CBCT) imaging. Ma et al (51) reported residual RMS errors from 0.17 to 0.30 mm (σ from 0.17 to 0.29 mm) for stereotactic X‐ray localization and 0.35 to 0.50 mm (σ from 0.33 to 0.48 mm) for CBCT localization. Kim et al (38) reported average errors from 0.2 to 0.8mm (σ from 0.2 to 0.4 mm) for stereotactic X‐ray localization and 0.0 to 0.6 mm (σ from 0.5 to 0.7 mm) for CBCT localization.…”
Section: Discussionmentioning
confidence: 99%
“…Several groups have evaluated positioning accuracies of independent IGRT methodologies utilizing floor mounted stereotactic X‐ray localization and gantry‐mounted volumetric (CBCT) imaging. Ma et al (51) reported residual RMS errors from 0.17 to 0.30 mm (σ from 0.17 to 0.29 mm) for stereotactic X‐ray localization and 0.35 to 0.50 mm (σ from 0.33 to 0.48 mm) for CBCT localization. Kim et al (38) reported average errors from 0.2 to 0.8mm (σ from 0.2 to 0.4 mm) for stereotactic X‐ray localization and 0.0 to 0.6 mm (σ from 0.5 to 0.7 mm) for CBCT localization.…”
Section: Discussionmentioning
confidence: 99%
“…4 In December of 2009, the Novalis Tx system (BrainLAB, Varian, Palo Alto, CA, USA), a recently available dedicated platform for image-guided SRS and conventional radiotherapy, was installed in place of the m3 system. [5][6][7][8][9][10][11] This system is equipped with an integrated high-defi nition (HD) mMLC (HD120). [6][7][8][9][10] The m3 mMLC systems, also integrated in the Novalis predecessor system, have a 3 mm leaf width for the central 4.2 cm of the beam, whereas the HD120 mMLC has a 2.5 mm leaf width for the central 8 cm.…”
Section: Introductionmentioning
confidence: 99%
“…Figure 1 shows the system evaluated in this study with the dual kV planar imaging system labeled in red with an A and B. The ExacTrac system comes equipped with two ceiling mounted 25.5.15emcm×25.5.15emcm aSi flat panel detectors 8 , 14 and two corresponding kV X‐ray tubes that project medially, anteriorly, and inferiorly (15) at oblique angles (45° from the mid‐sagittal plane of the accelerator 8 , 14 ) from the standard treatment position. The ExacTrac system is different with respect to traditional X‐ray systems in that: a) it has a large source‐to‐isocenter and source‐to‐detector distance (2.34 and 3.62 m, respectively (8) ); b) the detectors and X‐ray tubes are both in a fixed position; and c) the X‐rays project in an oblique direction relative to the patient (16) .…”
Section: Methodsmentioning
confidence: 99%