1985
DOI: 10.1016/0038-1098(85)90180-2
|View full text |Cite
|
Sign up to set email alerts
|

EXAFS of Cd1−xZnxTe: A test of the random distribution in zincblende ternary alloys

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
29
0

Year Published

2000
2000
2014
2014

Publication Types

Select...
5
4

Relationship

1
8

Authors

Journals

citations
Cited by 69 publications
(32 citation statements)
references
References 5 publications
3
29
0
Order By: Relevance
“…Microscopic, local structural information obtained by extended x-ray absorption fine-structure studies (EXAFS) of several alloys have indeed established beyond doubt that the first near-neighbor bond lengths [2][3][4], A-C and B-C, remain close to their values in the corresponding end-members instead of adopting a single average value. In a few reports, such analyses were extended up to the higher coordination shells [4,[43][44][45][46][47][48][49] to check if such discrepancies exist at longer interatomic distances. Distortions induced in a system due to doping not only affects the interatomic distances but also the angles contained by them, which tend to buckle accordingly [2,[50][51][52][53][54][55], deviating from their ideal bond angle values.…”
Section: Introductionmentioning
confidence: 99%
“…Microscopic, local structural information obtained by extended x-ray absorption fine-structure studies (EXAFS) of several alloys have indeed established beyond doubt that the first near-neighbor bond lengths [2][3][4], A-C and B-C, remain close to their values in the corresponding end-members instead of adopting a single average value. In a few reports, such analyses were extended up to the higher coordination shells [4,[43][44][45][46][47][48][49] to check if such discrepancies exist at longer interatomic distances. Distortions induced in a system due to doping not only affects the interatomic distances but also the angles contained by them, which tend to buckle accordingly [2,[50][51][52][53][54][55], deviating from their ideal bond angle values.…”
Section: Introductionmentioning
confidence: 99%
“…Theoretical predictions such as alloy structural disorder due to the bond relaxation [9], have been confirmed by extended X-ray-absorption fine structure (EXAFS) measurements of nearest-neighbour distances for Cd 1−x Zn x Te [10]. According to the work of Comedi and Kalish [11], the thermal vibrational amplitudes are expected to be determined mainly by the bonding properties of the crystal and not by dislocation kinetics.…”
Section: Introductionmentioning
confidence: 77%
“…Evolution of the bond length with changing composition is more pronounced in the mixed crystals containing Zn. This effect was observed and discussed in several systems like Zn 1−x Hg x Te [48], Zn 1−x Mn x Se [49], Zn 1−x Mn x Te [50,51], and Cd 1−x Zn x Te mixed crystals [44,[52][53][54][55]. At least the recent experimental data for Cd 1−x Zn x Te clearly suggest also a non-linear variation of the bond lengths with the mixed crystal composition [55].…”
Section: The Effect Of the Mixed Crystal Compositionmentioning
confidence: 87%