1987
DOI: 10.1016/0168-9622(87)90027-3
|View full text |Cite
|
Sign up to set email alerts
|

Examination of some proposed K-Ar standards: analyses and conventional KAr data

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
78
1

Year Published

1988
1988
2017
2017

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 116 publications
(80 citation statements)
references
References 6 publications
1
78
1
Order By: Relevance
“…About 1.5 to 3 gm of 40-120 mesh from each sample was wrapped in aluminum foil packets and stacked in aluminum canister with LP-6 biotite standard (127.7 ± 1.4 Ma, Odin, 1982) and HDB-1 biotite (24.7 ± 0.4 Ma, Fuhrmann et al, 1987) and irradiated in the Open Pool Reactor at National Tsing-Hua University with neutron flux of 1.566 × 10 13 n/cm 2 sec for 8 hours. After irradiation, samples were loaded in degassed fused silica boats, and placed into a degassed fused quartz tube, baked at 250°C for 24 hours and then incrementally heated following a 30-min.…”
Section: Samples and Analytical Methodsmentioning
confidence: 99%
“…About 1.5 to 3 gm of 40-120 mesh from each sample was wrapped in aluminum foil packets and stacked in aluminum canister with LP-6 biotite standard (127.7 ± 1.4 Ma, Odin, 1982) and HDB-1 biotite (24.7 ± 0.4 Ma, Fuhrmann et al, 1987) and irradiated in the Open Pool Reactor at National Tsing-Hua University with neutron flux of 1.566 × 10 13 n/cm 2 sec for 8 hours. After irradiation, samples were loaded in degassed fused silica boats, and placed into a degassed fused quartz tube, baked at 250°C for 24 hours and then incrementally heated following a 30-min.…”
Section: Samples and Analytical Methodsmentioning
confidence: 99%
“…The amount of radiogenic 40 Ar was determined by isotope dilution method using a highly enriched 38Ar spike . The spike is calibrated against the biotite standard HD-B1 (Fuhrmann et al 1987). The age calculations are based on the constants recommended by the IUGS quoted in .…”
Section: Discussionmentioning
confidence: 99%
“…The amount of radiogenic 40 Ar was determined by isotope dilution method using a highly enriched 38 Ar spike (Schumacher, 1975), which was calibrated against the biotite standard HD-B1 (Fuhrmann et al, 1987;Hess and Lippolt, 1994). The released gases were subjected to a two-stage purification procedure via Tigetters and SORB-ACs getters.…”
Section: K-ar Fault Gouge: Data Acquisitionmentioning
confidence: 99%