Abstract:Excess heat capacity in a bolometric detector has the consequence of increasing or leading to multiple device time constants. The Mo/Au bilayer transition edge sensor (TES) bolometric detectors initially fabricated for the high resolution mid-infrared spectrometer (HIRMES) exhibited two response thermalization scales, one of which is a few times longer than estimates based upon the properties of the bulk materials employed in the design. The relative contribution of this settling time to the overall time respo… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.