2010
DOI: 10.1016/j.applthermaleng.2010.05.017
|View full text |Cite
|
Sign up to set email alerts
|

Exergy analysis of a heat transformer for water purification increasing heat source temperature

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
7
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 43 publications
(8 citation statements)
references
References 15 publications
1
7
0
Order By: Relevance
“…The SSHT's ECOP shows similar trends to the COP, increasing (initially quite rapidly [8]) with an increase in the evaporator and generator temperatures before beginning to decrease [23,24], and increasing with a decrease in condensation temperature [24]. The ECOP also decreases slightly with an increase in absorber temperature (i.e.…”
Section: Ssht Parametric Studiessupporting
confidence: 58%
See 1 more Smart Citation
“…The SSHT's ECOP shows similar trends to the COP, increasing (initially quite rapidly [8]) with an increase in the evaporator and generator temperatures before beginning to decrease [23,24], and increasing with a decrease in condensation temperature [24]. The ECOP also decreases slightly with an increase in absorber temperature (i.e.…”
Section: Ssht Parametric Studiessupporting
confidence: 58%
“…The ECOP also decreases slightly with an increase in absorber temperature (i.e. the GTL), before beginning to fall off rapidly once some critical absorber temperature is reached [24].…”
Section: Ssht Parametric Studiesmentioning
confidence: 99%
“…Eqs. (4) and (5) indicate that the value of e EC1 and e EC2 are related to the inlet solution temperature of the absorber and the absorber-evaporator, respectively, as T gen stays unchanged. Furthermore, the e EC1 and e EC2 have different influence on the OAET although they are similar in variation trends.…”
Section: Resultsmentioning
confidence: 99%
“…The large consumption of the fossil fuel is not only unsustainable but also pollutes the environment. In this respect, many countries are investing a considerable amount of money to develop equipments to use energy efficiently and to apply to renewable energy [2][3][4][5][6][7][8]. Among these devices, absorption heat transformer (AHT) is very promising since it can utilize waste heat or renewable energy, like solar energy and geothermal energy, to provide high temperature heat [9][10][11].…”
Section: Introductionmentioning
confidence: 99%
“…The outlet temperature of the Kalina cycle from the evaporator, depending on the design and operating conditions, can vary between 75 and 80 °C. This temperature range may be suitable for a LiBr/H 2 O absorption heat transformer in seawater desalination applications [24][25][26][27][28][29] but, to the best of our knowledge, this topic has not yet been investigated by researchers.…”
Section: Introductionmentioning
confidence: 99%