2016 International Conference on Energy Efficient Technologies for Sustainability (ICEETS) 2016
DOI: 10.1109/iceets.2016.7582941
|View full text |Cite
|
Sign up to set email alerts
|

Exergy analysis of a solar PV driven DC refrigerator for different ambient conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 6 publications
0
5
0
Order By: Relevance
“…The ARIMA model's biggest strengths are its elegance and simplicity. It is only possible to employ stationary time series [14,18,19]. In order to test the ARIMA model's applicability, we employ data from seasonal time series as well as non-stationary data that become fixed data.…”
Section: Figure 12 Forecasting Methodologiesmentioning
confidence: 99%
“…The ARIMA model's biggest strengths are its elegance and simplicity. It is only possible to employ stationary time series [14,18,19]. In order to test the ARIMA model's applicability, we employ data from seasonal time series as well as non-stationary data that become fixed data.…”
Section: Figure 12 Forecasting Methodologiesmentioning
confidence: 99%
“…Thus, DC compressors consume less power and eliminate the need for DC-AC converters. Previous studies have also recommended the use of DC compressors for solar PV refrigeration systems (Torres-Toledo et al 2016;Sidney and Mohan 2016;Daffallaha 2018;Li et al 2021) A major drawback of solar PV systems is the frequent failure of batteries used to store energy. The experimental results of Fezai et al (2021) elucidated that the battery bank of these systems plays a major role in their reliability and life cycle cost.…”
Section: Introductionmentioning
confidence: 99%
“…The introduction of DC compressors facilitates the direct utilization of green energy without inverters. 510 The operation of solar photovoltaic refrigerators with battery backup has been a hindrance for large scale usage due to bulky array of batteries, frequent battery failure resulting in replacement and disposal related problems. Axaopoulos et al.…”
Section: Introductionmentioning
confidence: 99%
“…20 Sidney et al. 10 performed exergy analysis on a bottle cooler run by a DC compressor with HC-600a refrigerant for different ambient temperatures. The maximum exergetic destruction was observed in the compressor followed by the evaporator, then the condenser and finally the expansion device.…”
Section: Introductionmentioning
confidence: 99%