1999
DOI: 10.1016/s0003-2670(99)00522-x
|View full text |Cite
|
Sign up to set email alerts
|

Expanding the working concentration range for the direct analysis of metallic alloys by on-line anodic electrodissolution and electrothermal atomic absorption spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2001
2001
2016
2016

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(2 citation statements)
references
References 26 publications
0
2
0
Order By: Relevance
“…The latter permits the determination of cadmium at both low (linear portion) and moderately-high (non-linear portion) concentrations with the same calibration curve. This is not possible with some methods which resort to decreasing the sensitivity of the measurements for increasing the LDR, thus allowing only the determination of elements at high concentrations [8,9]. Another advantage of modeling by ANNs is, in general, the fact that no a priori knowledge of the system is required ("soft" modeling), as it is when modeling by conventional mathematical methods ("hard" modeling).…”
Section: Determination Of CD By Gfaas In a Certified Reference Materialsmentioning
confidence: 99%
See 1 more Smart Citation
“…The latter permits the determination of cadmium at both low (linear portion) and moderately-high (non-linear portion) concentrations with the same calibration curve. This is not possible with some methods which resort to decreasing the sensitivity of the measurements for increasing the LDR, thus allowing only the determination of elements at high concentrations [8,9]. Another advantage of modeling by ANNs is, in general, the fact that no a priori knowledge of the system is required ("soft" modeling), as it is when modeling by conventional mathematical methods ("hard" modeling).…”
Section: Determination Of CD By Gfaas In a Certified Reference Materialsmentioning
confidence: 99%
“…Among the various approaches are worth mentioning: the use of peak area instead of peak height [5], high-pressure atomizers [6,7], quantitation at non-resonant absorption lines [8,9], non-stop gas condition during atomization [8], atomization off the platform or the atomizer wall [8,9], mathematical corrections of the cause of deviations from linearity [10][11][12], and less often modeling of the calibration curve with polynomial expressions [4,13,14].…”
Section: Introductionmentioning
confidence: 99%