2010
DOI: 10.2478/v10187-010-0042-3
|View full text |Cite
|
Sign up to set email alerts
|

Experience with Imaging by Using of Microfocus X-Ray Source

Abstract: In this paper we present the current work and experience with using microfocus x-ray generator and commercial CCD camera for x-ray imaging purpose. There is a need in laboratories for the development of imaging methods approaching synchrotron radiation sources, where the brilliance of radiation is on very high-level. Generally, there is no continuous access to synchrotron facilities. Several synchrotron radiation laboratories allocate the access via a proposal system. Thus the time for synchrotron radiation ex… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
3
0

Year Published

2012
2012
2015
2015

Publication Types

Select...
2
1

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 5 publications
1
3
0
Order By: Relevance
“…It has a very regular internal structure as shown in figure 7. Results of measurements of the spatial resolution presented in [5] are confirmed by this CT experiment. We can recognize a wall thickness of the wood cells about 3 µm (see figure 7a).…”
Section: Phase Contrast Modesupporting
confidence: 73%
See 2 more Smart Citations
“…It has a very regular internal structure as shown in figure 7. Results of measurements of the spatial resolution presented in [5] are confirmed by this CT experiment. We can recognize a wall thickness of the wood cells about 3 µm (see figure 7a).…”
Section: Phase Contrast Modesupporting
confidence: 73%
“…An important prerequisite for high resolution CT is high spatial resolution of the 2D projections which is possible by using an optical magnification of the object. With the present set-up it is possible to achieve the spatial resolution of the whole X-ray imaging system down to 3 µm [5]. There is a possibility to express the so-called CT voxel size as the ratio of CCD pixel size and magnification factor of the imaging setup.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…1 This was the motivation for the x-ray microscopy setup we developed, which is based on an x-ray microfocus generator attaining a spatial resolution down to 3 μm with an average lateral coherence length of 0.3 to 13 μm and up to a 140-fold geometrical magnification. 2,3 However, such a setup uses broad polychromatic radiation, therefore, the extracted quantities from the x-ray images, such as attenuation coefficient and the retrieved phase, are affected by beam hardening effects and the x-ray images have usually a reduced contrast due to the presence of scattering. The use of monochromatic radiation will, therefore, be of benefit but at the cost of a significant photon flux loss.…”
Section: Introductionmentioning
confidence: 99%