2013
DOI: 10.1016/j.ijthermalsci.2012.12.014
|View full text |Cite
|
Sign up to set email alerts
|

Experiment study of an enhanced vapor injection refrigeration/heat pump system using R32

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0
4

Year Published

2016
2016
2022
2022

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 60 publications
(12 citation statements)
references
References 14 publications
0
8
0
4
Order By: Relevance
“…Several basic cycle configuration modifications have been proposed to decrease the discharge temperature and in the same time, increase the energy performance of the air conditioning system using R32. Shuxue et al (2013) quantified the discharge temperature reduction by the use of enhanced vapor injection between 10 and 20 K but Xu et al (2013) only measured energy performance improvement using this configuration at non-extreme cooling and heating conditions. Yang et al (2015) concluded that two-phase injection outperforms liquid injection ( Figure 11) and two-phase suction in both cooling capacity and COP by 12% and 5%.…”
Section: Single Split Air Conditioning Systems Containing Less Than 3mentioning
confidence: 99%
See 1 more Smart Citation
“…Several basic cycle configuration modifications have been proposed to decrease the discharge temperature and in the same time, increase the energy performance of the air conditioning system using R32. Shuxue et al (2013) quantified the discharge temperature reduction by the use of enhanced vapor injection between 10 and 20 K but Xu et al (2013) only measured energy performance improvement using this configuration at non-extreme cooling and heating conditions. Yang et al (2015) concluded that two-phase injection outperforms liquid injection ( Figure 11) and two-phase suction in both cooling capacity and COP by 12% and 5%.…”
Section: Single Split Air Conditioning Systems Containing Less Than 3mentioning
confidence: 99%
“…Barve and Cremaschi, 2012 Park et al, 2015Qv et al, 2017Shuxue et al, 2013Wu et al, 2016Xu et al, 2013Yang et al, 2015Zilio et al, 2015…”
Section: R32mentioning
confidence: 99%
“…The ASHP type has to be appropriate to work in cold climate. The key element of such a construction is the electronically controlled compressor with EVI (enhanced vapour injection) technology [20]. • GSHP-Ground source heat pump with vertical exchanger using energy accumulated in the ground for heating and domestic hot water preparation.…”
Section: Building Variantsmentioning
confidence: 99%
“…Shuxue et al [61] found that the enhanced vapour injection reduces the discharge temperature by [10,20] K. In addition, the best range of relative vapour injection mass is [12,16]% for the best overall cooling and heating performance (it changes the evaporating and condensing temperatures by [0.8, 1] K). Xu et al [62] found that the capacity and COP (both cooling and heating) improvements using R32 can reach up to 10% and 9% using a vapour-injected HP system.…”
Section: Performance and Discharge Temperature Concern Of Pure R32mentioning
confidence: 99%