2017
DOI: 10.1016/j.enconman.2017.03.013
|View full text |Cite
|
Sign up to set email alerts
|

Experimental activity at test rig validating correlations to select pumps running as turbines in microhydro plants

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
95
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 108 publications
(95 citation statements)
references
References 13 publications
0
95
0
Order By: Relevance
“…Another limitation of the methodology is the fact that while many theoretical PAT BEPs were analysed among the possible combinations of flow across the irrigation season, a finite number of pumps exist in the market. The PAT curves were obtained using Equation (10), which is based on experimental data from 12 pumps tested as turbines [32]. In reverse these pumps function as PATs and are considerably cheaper than traditional turbines due to mass production.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…Another limitation of the methodology is the fact that while many theoretical PAT BEPs were analysed among the possible combinations of flow across the irrigation season, a finite number of pumps exist in the market. The PAT curves were obtained using Equation (10), which is based on experimental data from 12 pumps tested as turbines [32]. In reverse these pumps function as PATs and are considerably cheaper than traditional turbines due to mass production.…”
Section: Discussionmentioning
confidence: 99%
“…Hence, l different scenarios were defined, each of them corresponding to one PAT, whose BEP was (Q lBEP , H BEP ). To regulate the PAT inlet conditions and keep the network service conditions downstream, the bypass scheme proposed by Lydon et al [32], has been considered, in which there are two control valves, one before the PAT and the other in parallel. The regulation used was hydraulic regulation (HR), since previous investigations concluded that HR is generally more efficient than electric regulation, showing larger efficiencies when the working conditions vary from the design values.…”
Section: Pat Operating Conditions Analysismentioning
confidence: 99%
See 2 more Smart Citations
“…A sample of 12 pumps was measured at the hydraulic test rig of the University of Calabria (UNICAL) in direct and reverse operation [19], measurements for 4 other pumps were found in [20], while the remaining 11 in [13].…”
Section: Journal Of Sustainable Development Of Energy Water and Envimentioning
confidence: 99%