2018
DOI: 10.1016/j.ref.2018.03.003
|View full text |Cite
|
Sign up to set email alerts
|

Experimental analysis for augmentation of heat transfer in multiple discrete V-patterns combined with staggered ribs solar air heater

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 41 publications
(6 citation statements)
references
References 29 publications
0
5
0
Order By: Relevance
“…Patel and Lanjewar 63,73,74 carried out a series of experimental studies with the objective of enhancing the thermo-hydraulic performance of a SAH that had been deliberately roughened with an array of discontinuous V-shaped ribs along with staggered elements. The researchers came to the conclusion that the Nu value and the friction factor had a close connection with the relative length of the staggered ribs as well as the number of gaps.…”
Section: Pec Numentioning
confidence: 99%
“…Patel and Lanjewar 63,73,74 carried out a series of experimental studies with the objective of enhancing the thermo-hydraulic performance of a SAH that had been deliberately roughened with an array of discontinuous V-shaped ribs along with staggered elements. The researchers came to the conclusion that the Nu value and the friction factor had a close connection with the relative length of the staggered ribs as well as the number of gaps.…”
Section: Pec Numentioning
confidence: 99%
“…Patel and Lanjewar7072Jain and Lanjewar 73 were carried out their investigation for V-down with symmetrical gaps and combined with staggered rib roughness geometry SAH which is shown supplementary Fig. 26.…”
Section: Application Of Wire Ribs and Its Different Geometries In Sah...mentioning
confidence: 99%
“…On the other hand, the results of Pandey et al 25 indicate that the highest increment in friction factor and Nusselt number obtained by using this type of roughness are equal 4.96 and 5.85 times of smooth duct. Furthermore, Patel and Lanjewar 26 they have found that the highest enhancement in Nusselt number and friction factor are equal 2.27 and 4.28 times of smooth duct. Ravi and Saini 27 examined the impacts of roughness coefficients on the thermal‐hydraulic performance of double‐pass collector with a discrete multi V‐shaped and staggered rib and compared with smooth ducts.…”
Section: Introductionmentioning
confidence: 96%