Experimental Analysis of Endovascular Treatment of AAA and Predictors of Long Term Outcomes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2019
2019
2020
2020

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(4 citation statements)
references
References 59 publications
0
4
0
Order By: Relevance
“…For instance, in a conical vessel there is always the trade-off between SG undersizing, that is, too little SG oversizing, at the wide end of the vessel and excessive SG oversizing at the narrow end of the vessel. This means there is always a trade-off between complications associated with SG undersizing, 7,50 such as SG migration and endoleaks, and complications related to excessive SG oversizing, 27,51 such as postinterventional aortic neck dilatation. It was shown that by using second level customized SGs this inconsistency in choosing the degree of SG oversizing is obsolete.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…For instance, in a conical vessel there is always the trade-off between SG undersizing, that is, too little SG oversizing, at the wide end of the vessel and excessive SG oversizing at the narrow end of the vessel. This means there is always a trade-off between complications associated with SG undersizing, 7,50 such as SG migration and endoleaks, and complications related to excessive SG oversizing, 27,51 such as postinterventional aortic neck dilatation. It was shown that by using second level customized SGs this inconsistency in choosing the degree of SG oversizing is obsolete.…”
Section: Discussionmentioning
confidence: 99%
“…Further, smaller degree of SG oversizing could be used for customized SGs to obtain the same passive fixation forces between SG and vessel and hence reduce potential negative effects of large SG oversizing. 7,27,51 The smallest impact of SG customization was identified for straight and elliptical vessels. It is explained by the relatively small lateral stiffness of a cylindrical SG.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…In contrast, EVAR is considered to be successful if the aneurysm stays excluded and has no expansion for several years after the intervention. Reasons for immediate or long-term failure of EVAR are difficult to identify, but both wrong SG sizing [1][2][3][4] and inappropriate vessel morphologies [5][6][7] are frequent explanations in literature. Device manufacturers formulate the limits of applicability of EVAR in their instructions for use (IFU), 5,8 which state, for instance, that the aortic neck should not exceed a certain angle and that the neck requires a certain minimum length.…”
Section: Introductionmentioning
confidence: 99%