2008
DOI: 10.1088/0957-0233/19/8/085502
|View full text |Cite
|
Sign up to set email alerts
|

Experimental analysis of high-speed gamma-ray tomography performance

Abstract: High-speed gamma-ray tomography (HSGT) based on multiple fan-beam collimated radioisotope sources has proved to be an efficient and fast method for cross sectional imaging of the dynamics in different industrial processes. The objective of the tomography system described here is to identify the flow regime of gas/liquid pipe flows. The performance of such systems is characterized by the spatial resolution, the speed of response and the measurement resolution of the attenuation coefficient. The work presented h… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2010
2010
2021
2021

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 23 publications
(13 citation statements)
references
References 12 publications
0
13
0
Order By: Relevance
“…Once this is completed for each pixel in the measurement region, the solution is presented as a pair of temperature and concentration images. The quality of these reconstructions is quantified using the root mean-squared-error (RMSE) [32]:…”
Section: Methodsmentioning
confidence: 99%
“…Once this is completed for each pixel in the measurement region, the solution is presented as a pair of temperature and concentration images. The quality of these reconstructions is quantified using the root mean-squared-error (RMSE) [32]:…”
Section: Methodsmentioning
confidence: 99%
“…The working principle of g-ray CT is similar to X-ray CT with the difference that the X-ray tube is replaced by an isotopic g-ray source. Systems of this type have been developed and applied by several groups, see for example, Kumar, Moslemian, and Dudukovic (1995), Al-Dahhan et al (2007), Hampel et al (2007), Bieberle, Hoppe, Schleicher, and Hampel (2011), Bieberle, Schleicher, and Hampel (2007), Johansen, Hjertaker, Froystein, and Olsen (1996), Johansen, Hampel, and Hjertaker (2010, and Maad and Johansen (2008). The actual velocity field estimation in X-ray and g-ray imaging modalities is done indirectly by analysing a sequence of images with, for example, cross-correlation techniques explained above.…”
Section: Optical Flow Metersmentioning
confidence: 99%
“…It can be shown that this expression has a minimum when the product µr equals 2 [16]. Using data from associated the plot in [17] it is shown that the optimal path length Table 1 Tomograms reconstructed from polypropylene phantom, using the ILST algorithm with eight iterations on a 32 × 32 grid for different sensor data integration times and variable rotational speed. The RMSE is calculated for each image.…”
Section: Dynamic Characterization Of a Rotational Motionmentioning
confidence: 99%