2018
DOI: 10.1177/2280800018793816
|View full text |Cite
|
Sign up to set email alerts
|

Experimental assessment of biomechanical properties in human male elbow bone subjected to bending and compression loads

Abstract: This work discusses the biomechanical testing of 3 elbow bones, namely the humerus, ulna, and radius. There is a need to identify the mechanical properties of the bones at the organ level. The following tests were performed: 3-point bending, fracture toughness, and axial compression. Six sets of whole-bone samples of human male cadaveric humerus, ulna, and radius (age of donor: 35 to 56 years) were tested. The results were analyzed for statistical significance by 2-stage, repeated-measure analysis of variance … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
28
1
1

Year Published

2019
2019
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 21 publications
(32 citation statements)
references
References 56 publications
(93 reference statements)
2
28
1
1
Order By: Relevance
“…Clearly, compared with PEKK and PT20, PT40 containing high Ta content exhibited optimized surface performances. Furthermore, PT40 with high Ta content had improved mechanical performances (e.g., compressive strength and modulus of elasticity), which is close to the cortical bone of human [ 26 , 27 ]. In short, PT40 with excellent biocompatibility, improved mechanical performances and bioactivity stimulated cell responses, and promoted osseointegration, which might have tremendous potential for bear-loading bone substitute.…”
Section: Discussionmentioning
confidence: 97%
“…Clearly, compared with PEKK and PT20, PT40 containing high Ta content exhibited optimized surface performances. Furthermore, PT40 with high Ta content had improved mechanical performances (e.g., compressive strength and modulus of elasticity), which is close to the cortical bone of human [ 26 , 27 ]. In short, PT40 with excellent biocompatibility, improved mechanical performances and bioactivity stimulated cell responses, and promoted osseointegration, which might have tremendous potential for bear-loading bone substitute.…”
Section: Discussionmentioning
confidence: 97%
“…Therefore, stress values on the human arm when Nurse reaches critical positions are negligible with respect to the mentioned mechanical properties of the skeletal muscles. On the other hand, the achieved stress values are negligible with respect to the average bending strength (the material's ability to withstand stress) of the humerus (128,430 × 10 3 N/m 2 ), ulna (135,160 × 10 3 N/m 2 ), and radius (80,310 × 10 3 N/m 2 ) [50]. In summary, the stress results show that the Nurse operation is safe for the human arm.…”
Section: Operation Safetymentioning
confidence: 98%
“…Для задач статики вона має вигляд (2) [11][12][13]: Фізико-механічні властивості прошарків моделі (табл. 1), а також характер навантаження моделі для всіх розрахунків були прийняті постійними [3,[14][15][16][17][18]. Аналізували варіанти навантаження плечової кістки в положенні нейтральної ротації з кутами відведення в плечовому суглобі 0°, 30°, 60° і 90°.…”
Section: матеріал і методиunclassified