2019
DOI: 10.1017/jfm.2019.836
|View full text |Cite
|
Sign up to set email alerts
|

Experimental data for solid–liquid flows at intermediate and high Stokes numbers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
2
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(5 citation statements)
references
References 98 publications
2
2
1
Order By: Relevance
“…Profiles of (a) the TKE in single-phase and particle-laden turbulent channel flows and (b) the relative change of the TKE with respect to the single-phase flow, i.e. (k − k sp )/k sp , at a/H = 0.05, Φ 0 = 2.36 %, Re b = 5746 and ρ r = 2.0. the near-wall region can be observed in figure 8, as also observed in previous experiments(Tsuji et al 1984;Hosokawa & Tomiyama 2004;Mena & Curtis 2020). As u i /u b increases, the region for turbulence enhancement is expanded.…”
supporting
confidence: 84%
See 3 more Smart Citations
“…Profiles of (a) the TKE in single-phase and particle-laden turbulent channel flows and (b) the relative change of the TKE with respect to the single-phase flow, i.e. (k − k sp )/k sp , at a/H = 0.05, Φ 0 = 2.36 %, Re b = 5746 and ρ r = 2.0. the near-wall region can be observed in figure 8, as also observed in previous experiments(Tsuji et al 1984;Hosokawa & Tomiyama 2004;Mena & Curtis 2020). As u i /u b increases, the region for turbulence enhancement is expanded.…”
supporting
confidence: 84%
“…One can see that our criterion agrees well with the experimental data and the numerical data of Uhlmann (2008). There is some discrepancy between our criterion and the recent experiment of Mena & Curtis (2020). At the moment, the reason is not clear.…”
Section: Criterion For Turbulence Modulationsupporting
confidence: 61%
See 2 more Smart Citations
“…Indeed, this is briefly discussed in the paper when the results for the highest particle size (200 µm) showed signs of a lack of fully developed flow. In the work performed by Mena and Curtis [56], it was postulated and concluded that 51 pipe diameters were sufficient for fully developed flow, and they measured this by the use of pressure transducers placed periodically along the pipe. In the study, they used water as the carrier fluid; therefore, the viscous effects were significantly higher than air, and particle slip velocity would be less of a concern.…”
Section: Particle Full Developmentmentioning
confidence: 99%