2012
DOI: 10.1016/j.fluid.2012.07.008
|View full text |Cite
|
Sign up to set email alerts
|

Experimental density and PC-SAFT modeling of Krytox® (perfluoropolyether) at pressures to 275MPa and temperatures to 533K

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
26
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 23 publications
(27 citation statements)
references
References 29 publications
1
26
0
Order By: Relevance
“…Two slightly different high-pressure view cells are used in this study and have been described in detail elsewhere [8,9,[14][15][16]. The only difference between the cells is that the sapphire window on one cell is sealed with an elastomeric o-ring whereas the other cell uses a window holder that eliminates the need for the o-ring.…”
Section: Experimental Methodsmentioning
confidence: 99%
“…Two slightly different high-pressure view cells are used in this study and have been described in detail elsewhere [8,9,[14][15][16]. The only difference between the cells is that the sapphire window on one cell is sealed with an elastomeric o-ring whereas the other cell uses a window holder that eliminates the need for the o-ring.…”
Section: Experimental Methodsmentioning
confidence: 99%
“…A total of 3825 data points of density data (Morgado et al, 2007(Morgado et al, , 2011Yokoyama and Takahashi, 1991;Holcomb and Van Poolen, 1994;Tamatsu et al, 1992;Ribeiro et al, 2007;Yin and Wu, 2011;Widiatmo et al, 2001;Bobbo et al, 2004;Kayukawa et al, 2003;Ohta et al, 2001;Pineiro et al, 2003Pineiro et al, , 2004Bamgbade et al, 2012; NIST Thermophysical Properties of Fluid Systems) from 5 different categories including HCFCs, HFCs, HFEs, PFAs, and PFAAs at several temperatures and pressures, corresponding to 48 different refrigerant systems have been used to train, validate and test the model. Table 1 shows the structural groups used as input variables.…”
Section: Application Of Ann On the Experimental Datamentioning
confidence: 99%
“…Same in principles of density determination with bellow volumometer, floating-piston densimeter also uses volume displacement information to measure densities, either by fixing the temperature and continuously changing the volume and pressure [4][5][6][7][48][49][50][51][52][53][54], or by keeping the volume fixed and changing the pressure and temperature [55][56][57][58]. The former method that fixes the temperature and changes the volume and pressure is more commonly used, giving waiting longer time needed for a change in temperatures.…”
Section: Floating-piston Densimetermentioning
confidence: 99%