2014
DOI: 10.1016/j.crme.2014.01.013
|View full text |Cite
|
Sign up to set email alerts
|

Experimental detection of flow separation over a plain flap by wall shear stress analysis with and without steady blowing

Abstract: Separation flow controlExperimental detection of flow separation over a plain flap by wall shear stress analysis with and without steady blowing Détection expérimentale du décollement de l'écoulement sur un volet sans fente par l'analyse du frottement pariétal avec ou sans soufflage continu

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 8 publications
(3 citation statements)
references
References 18 publications
0
3
0
Order By: Relevance
“…11 summarizes the results previously evoked. As explained in Chabert et al (2014b), there is not enough pressure taps (especially on the flap hinge) to provide better than an estimate of the lift coefficient, denoted by C * L . The evolution of the estimated lift coefficient C * L is plotted as a function of forcing frequency f + for a flap deflection angle δ = 37 • in Fig.…”
Section: Effect Of Forcing Frequency On Liftmentioning
confidence: 99%
“…11 summarizes the results previously evoked. As explained in Chabert et al (2014b), there is not enough pressure taps (especially on the flap hinge) to provide better than an estimate of the lift coefficient, denoted by C * L . The evolution of the estimated lift coefficient C * L is plotted as a function of forcing frequency f + for a flap deflection angle δ = 37 • in Fig.…”
Section: Effect Of Forcing Frequency On Liftmentioning
confidence: 99%
“…[9][10][11]). Flow separation occurring because of a large adverse pressure gradient such as observed for two-dimensional flap ( [12][13][14][15][16]) constitutes one of the standard 5009 benchmark for development of new actuators or advanced control strategies [4,5,17,18] and [19]. This configuration will be considered in the present paper as a test case to apply recently developed methods of the Control Theory.…”
Section: Introductionmentioning
confidence: 99%
“…Among the various strategies developed, those using pneumatic actuators, such as air blowers, are the most encountered. In the meantime, the preferred examined system concerns flow separating over a two-dimensional flap (see [1], [2], [3], [4] and [5]). These works generally study the system from the Fluid Mechanics point of view but the application of control theory should be fruitfull to control the opening and closing of the air blowers in an optimal and robust way.…”
Section: Introductionmentioning
confidence: 99%