2010
DOI: 10.2298/tsci1001039v
|View full text |Cite
|
Sign up to set email alerts
|

Experimental evaluation of internal heat exchanger influence on R-22 window air conditioner retrofitted with R-407C

Abstract: a De part ment of Me chan i cal En gi neer ing, Gov ern ment Col lege of En gi neer ing, Sa lem, In dia b KSR Col lege of Tech nol ogy, Thiruchengode, In dia Orig i nal sci en tific pa per UDC: 697.97:66.045.1The per for mance of one ton of re frig er a tion win dow air con di tioner work ing with R-22 and retro fit ted with eco friendly al ter na tive re frig er ant R-407C is ex per i mentally in ves ti gated An in ter nal heat exchanger is also added to the same air con ditioner to pro vide liq uid over feed… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2012
2012
2020
2020

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 5 publications
0
2
0
Order By: Relevance
“…Yousef et al [20] analyzed the comparative performance of the four refrigerants: R-22, R-134a, R-407C, and R-410A, as alternative cooling fluids in a condenser in a steam power plant. Vijayan and Srinivasan [21] experimentally investigated the performance of R-22 and R-407C in a window A/C system that was originally charged with R-22 but later charged with R-407C. They found that the coefficient of performance increased, and the power requirement and pressure ratio of the compressor were reduced.…”
Section: Introductionmentioning
confidence: 99%
“…Yousef et al [20] analyzed the comparative performance of the four refrigerants: R-22, R-134a, R-407C, and R-410A, as alternative cooling fluids in a condenser in a steam power plant. Vijayan and Srinivasan [21] experimentally investigated the performance of R-22 and R-407C in a window A/C system that was originally charged with R-22 but later charged with R-407C. They found that the coefficient of performance increased, and the power requirement and pressure ratio of the compressor were reduced.…”
Section: Introductionmentioning
confidence: 99%
“…This study revealed that circular tubes develop a secondary flow when the Dean number exceeds a critical value. Since then several experimental [4][5][6][7][8][9][10] and numerical [11- 16] studies have been conducted in attempts to examine the transport phenomena in the spiral tubes. Most of these studies deal with spiral ducts with the typical cross-sections being circular or rectangular.…”
Section: Introductionmentioning
confidence: 99%