Abstract: Purpose: The aim of this work was to experimentally demonstrate the feasibility of x-ray acoustic computed tomography (XACT) as a dosimetry tool in a clinical radiotherapy environment. Methods: The acoustic waves induced following a single pulse of linear accelerator irradiation in a water tank were detected with an immersion ultrasound transducer. By rotating the collimator and keeping the transducer stationary, acoustic signals at varying angles surrounding the field were detected and reconstructed to form a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
71
0
1

Year Published

2018
2018
2022
2022

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 38 publications
(72 citation statements)
references
References 31 publications
0
71
0
1
Order By: Relevance
“…While XACT using BP has been studied extensively due to its potential for relative dosimetry, it has not been studied for its potential for absolute dosimetry. By comparing results from both BP and ITR imaging algorithms for their accuracy in the dose reconstruction, we investigated the feasibility of using XACT imaging for absolute dosimetry.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…While XACT using BP has been studied extensively due to its potential for relative dosimetry, it has not been studied for its potential for absolute dosimetry. By comparing results from both BP and ITR imaging algorithms for their accuracy in the dose reconstruction, we investigated the feasibility of using XACT imaging for absolute dosimetry.…”
Section: Discussionmentioning
confidence: 99%
“…Also, the effects of acoustic noise on the accuracy of dose reconstruction are not investigated in this work. While noise is an important problem in XA imaging, it can be suppressed by filtering techniques or averaging the signal from multiple measurement …”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Later studies investigated using XACT to image dose distributions of various shapes and sizes in a homogeneous water tank . Experimental XACT images were obtained by keeping an immersion ultrasound transducer stationary while the linac collimator was rotated.…”
Section: Linac Photon Beam Dosimetrymentioning
confidence: 99%