“…Similarly, this observation was also made in the work of Hilpert et al on deaeration in RPBs with both a metal foam packing and an empty rotor; they found that an increase in k L a with gas-flow rate can be observed at sufficient n rot , possibly due to a combination of increased specific effective surface area and enhanced gas− liquid interaction, and thus mass transfer on a microscale. 42 Furthermore, it has been proven in the literature that the interfacial area increases with the gas flow; examples are a variety of countercurrently operated rotor internals like metal foam packings, 54 wire mesh packings, 14,20,28,55,56 blade supported packings 57 as well as the comparable rotor-stator reactor, 50 and RZB. 58 For all operating points above n pmin , the k L a value using 2SZP was highest among the packings studied.…”