Experimental Investigation of Critical Heat Flux on Different Surfaces at Low Pressure and Low Flow

Abstract: Steady state flow boiling experiments were carried out on several heated tubes with outer diameter 9.14 mm at outlet pressures 120, 200 and 300 kPa, inlet temperatures 64, 78 and 91 °C and approximately 400, 500, 600 and 800 kg/(m2·s) mass flux entering the vertically aligned test annulus until critical heat flux (CHF) was reached. The tubes were made of Inconel 625 with a length of 400 mm. The Inconel tubes were tested in three different modifications as smooth, abraded with 150 grit sandpaper and bead blaste… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 30 publications
0
4
0
Order By: Relevance
“…Presented data should serve as a reference for comparison with other materials including accident tolerant fuel [26]. The facility should be improved for ionex filters preventing the corrosive particles from depositing on test tubes and therefore extend the operation time with a clean surface as it was discussed in [21]. To obtain better flow stability and less oscillations, the inlet section will be slightly modified together with the change of the measuring probe.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…Presented data should serve as a reference for comparison with other materials including accident tolerant fuel [26]. The facility should be improved for ionex filters preventing the corrosive particles from depositing on test tubes and therefore extend the operation time with a clean surface as it was discussed in [21]. To obtain better flow stability and less oscillations, the inlet section will be slightly modified together with the change of the measuring probe.…”
Section: Resultsmentioning
confidence: 99%
“…The flow boiling experiments were performed on the Mobile Research Critical Heat Flux Apparatus (MR-CHA) which was constructed and operated by the University of Technology in Brno at Faculty of Electrical Engineering and Communication and its thorough description can be found in the article [21].…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations