2016
DOI: 10.1016/j.applthermaleng.2015.11.077
|View full text |Cite
|
Sign up to set email alerts
|

Experimental investigation of heat transfer and pressure drop in a circular tube with multiple inserts

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
24
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 113 publications
(25 citation statements)
references
References 21 publications
1
24
0
Order By: Relevance
“…They achieved the highest thermal performance factor of 1.34 for the range of tested Re . Similar studies were conducted by Vashistha et al using single, double, and four tapes with both the co‐swirl and counter‐swirl condition. They revealed that the counter swirl was better and also four tapes also gave a maximum value of the thermal performance factor.…”
Section: Introductionsupporting
confidence: 61%
See 1 more Smart Citation
“…They achieved the highest thermal performance factor of 1.34 for the range of tested Re . Similar studies were conducted by Vashistha et al using single, double, and four tapes with both the co‐swirl and counter‐swirl condition. They revealed that the counter swirl was better and also four tapes also gave a maximum value of the thermal performance factor.…”
Section: Introductionsupporting
confidence: 61%
“…In the initial phase of the study, the legitimacy of the numerically studied results for two tape conditions are validated by using the experimental results reported by Vashistha et al Numerical modeling was done using two twisted tape geometries under the co‐swirl condition with a twist ratio of 2.5 and retaining other design and flow conditions as specified by Vashistha et al Numerical simulation was conducted for different Reynolds numbers and heat transfer characteristics are analysed. Simulation and experimental results for Nusselt number ( Nu ) and friction factor ( f ) have been plotted and are shown in Figures and , respectively.…”
Section: Numerical Modelmentioning
confidence: 95%
“…The inlet water temperature and flow rate were separately set through changing the heaters and the water flow adjustment valve. And the data logger with computer was used to record data from these thermocouples persistently (Lim et al, 2007;Luo et al, 2015;Vashistha et al, 2016).…”
Section: Methodology 21 Laboratory Investigationmentioning
confidence: 99%
“…Chaitanya et al [16] investigated for HTC, FF and η for single, twin and four twisted tape insets at a time with twist ratio of 2, 3 and 3.5 for the Re in the range of 4000 to 14000. It was reported that as the number of twisted tape increases, the HTC augmentation and FF increases.…”
Section: Review On Multiple Twisted Tapes Insertsmentioning
confidence: 99%