2016
DOI: 10.2355/isijinternational.isijint-2015-691
|View full text |Cite
|
Sign up to set email alerts
|

Experimental Investigation of High-temperature Steel Plate Cooled by Multiple Nozzle Arrays

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 26 publications
0
4
0
Order By: Relevance
“…jet configuration and jet size, fluid flow rate or Reynolds number, surface and fluid temperature, fluid types, jet exit to surface spacing, surface orientation, and roughness etc . The commonly used fluids in jet impingement cooling are air and water, however, some research has also been reported with other fluids viz. fluorocarbons (FC), Freons, Nanofluids, and oil .…”
Section: Introductionmentioning
confidence: 99%
“…jet configuration and jet size, fluid flow rate or Reynolds number, surface and fluid temperature, fluid types, jet exit to surface spacing, surface orientation, and roughness etc . The commonly used fluids in jet impingement cooling are air and water, however, some research has also been reported with other fluids viz. fluorocarbons (FC), Freons, Nanofluids, and oil .…”
Section: Introductionmentioning
confidence: 99%
“…In addition, at the measurement point 14 in the three jet cross-interference region, the surface temperature decreased slowly at first, whereas subsequently to 1 s it decreased faster. This phenomenon was ascribed to the water flow higher violent vortex, which could effectively carry away the bubbles attached onto the hot plate surface 15) and increase both the boiling frequency and the heat extraction quantity.…”
Section: Surface Temperature and Htc Analysis For Threementioning
confidence: 99%
“…The cooling efficiency decreased along with the nozzle arrangement density, whereas the average heat flux did not increase monotonously along with the flow rate increase. Xie et al 15) studied the both the surface flow field and the heat transfer of a high temperature plate cooled by nine-nozzle arrays with various Reynolds numbers. The results demonstrated that the maximum heat flux, the corresponding surface temperature and time period at each measurement point were dependent on the distance from both the impinging point and the jet velocity.…”
Section: Local Heat Transfer Characteristics Of Multi Jet Impingementmentioning
confidence: 99%
“…[1][2][3][4] The UFC equipment impinges cooling water of 0.4-0.8 MPa onto plate surface of high-temperature through densely arranged nozzles to make steel quickly pass through austenite phase zone, and "freeze" hardened austenite to the dynamic transformation temperature of austenite to ferrite. [5][6][7][8] Increasing the cooling ability of UFC equipment can improve production efficiency and make the production of high-quality steel products possible. Lots of research had been done to improve the heat transfer performance of jet impingement.…”
Section: Introductionmentioning