2017
DOI: 10.1016/j.est.2017.09.010
|View full text |Cite
|
Sign up to set email alerts
|

Experimental investigation of parametric cell-to-cell variation and correlation based on 1100 commercial lithium-ion cells

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
73
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 166 publications
(74 citation statements)
references
References 40 publications
1
73
0
Order By: Relevance
“…These values were small compared to previous studies and in the literature [8,16,18,22]. The deviations in loading ratio values were small, below 2.5%, and no offset variations were measured (Figure 2b).…”
Section: Cell-to-cell Variationsmentioning
confidence: 64%
See 2 more Smart Citations
“…These values were small compared to previous studies and in the literature [8,16,18,22]. The deviations in loading ratio values were small, below 2.5%, and no offset variations were measured (Figure 2b).…”
Section: Cell-to-cell Variationsmentioning
confidence: 64%
“…The extent of initial cell-to-cell variations within a batch of cells, although not reported often enough, has been the topic of multiple studies in the literature [4][5][6][8][9][10][11][12][13]. Researchers have reported statistical studies on 12 [14], 50 [5,15,16], 100 [17][18][19][20], and 1000 [8][9][10]21] cells.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In order to achieve a stable configuration of a battery module or pack, a screening process is needed to ensure high homogeneity of the cells therein 11,22,23 . Several screening processes have been previously proposed 12,20,[24][25][26] . Multiple parameters, including capacity, mass, electrochemical impedance, direct current resistance and voltage, were employed to index the cell-to-cell variation.…”
mentioning
confidence: 99%
“…Multiple parameters, including capacity, mass, electrochemical impedance, direct current resistance and voltage, were employed to index the cell-to-cell variation. Rumpf et al 12 conducted a statistical analysis of parametric cell-to-cell variation of 15 different cell parameters and the correlations between parameters based on 1100 examined cells, and found it necessary to characterize variation in ohmic impedance when determining cell-to-cell variation. Dubarry et al 27,28 have conducted both statistical and electrochemical analyses to characterize cell-to-cell variations, and found that the cell capacity, resistance and rate capability can be regarded as three independent parameters for cell variations evaluation.…”
mentioning
confidence: 99%