2014
DOI: 10.1016/j.conbuildmat.2014.09.032
|View full text |Cite
|
Sign up to set email alerts
|

Experimental investigation of the first desorption isotherm of a high performance concrete with thin sliced samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 11 publications
(7 citation statements)
references
References 37 publications
0
7
0
Order By: Relevance
“…1. More experimental details are given in [46]. In general, the time required for mass stabilization is around 30 days at each relative humidity imposed in the present study.…”
Section: Mass Variation Kineticsmentioning
confidence: 99%
“…1. More experimental details are given in [46]. In general, the time required for mass stabilization is around 30 days at each relative humidity imposed in the present study.…”
Section: Mass Variation Kineticsmentioning
confidence: 99%
“…Note that the machining of thin specimen can increase the porous connectivity (Wu et al, 2014). However, microcracking mentioned previously above -item (i) -governs the increase in permeability in axial drying mode.…”
Section: Water Permeability Assessmentmentioning
confidence: 97%
“…Water absorption coefficient (%) Aggregates 12.5/ 25 2 Gravel 5/12.5 3 Sand 0/5 3 Fine sand <100 μm 3 Since the beginning of this programme in 2006, the use of thin section for the characterisation of desorption isotherms has been reported elsewhere (Ranaivomanana, Verdier, Sellier, & Bourbon, 2011;Wu, Rougelot, Burlion, & Bourbon, 2014).…”
Section: Samples Descriptionmentioning
confidence: 99%
“…This information proves to be hard to acquire experimentally mainly because the time required for the onset of water balance is too long (Baroghel-Bouny et al 1999;Baroghel-Bouny 2007;Trabelsi et al 2011;Poyet 2009;Poyet et al 2011;Sémété et al 2016). Many authors have attempted to gain time by diminishing the dimension of the tested samples (fine disks, powders, shreds) (Radjy et al 2003;Daïan 1988;BaroghelBouny et al 1999;Tada and Watanabe 2005;Espinosa and Franke 2006;Baroghel-Bouny 2007;Ishida et al 2007;Trabelsi et al 2011;Q. Wu et al 2014;Rougelot et al 2009;Sémété et al 2016).…”
Section: Introductionmentioning
confidence: 99%
“…Wu et al 2014;Rougelot et al 2009;Sémété et al 2016). Nevertheless, this approach does pose a problem of parasitic carbonation during the tests and calls for particular precaution: injection of inert gas for instance (Ranaivomanana et al 2011;Brue et al 2012;Q. Wu et al 2014).…”
Section: Introductionmentioning
confidence: 99%